CoChat

Highly sensitive humidity sensor based on amorphous Al2O3nanotubes

Cheng, Baochang, Tian, Baixiang, Xie, Cuicui, Xiao, Yanhe, Lei, Shuijin · 2011 · J. Mater. Chem.
Cited by 142

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Amorphous Al2O3 nanotubes were obtained by the transformation of NH4Al(OH)2CO3 nanotubes annealed at 600 °C. The tube-like nanostructures not only increase efficient sites for gas adsorption, but also promote the dissociation of water absorbed onto the surfaces of the nanotube walls. Moreover, they also provide effective and fast channels for vapor and liquid transport. Therefore, the sensors based on Al2O3 nanotubes show high sensitivity and fast response/recovery time to humidity. The impedance changes approximately four orders of magnitude as relative humidity (RH) varies from 11% to 95% at the measured frequency of 40 Hz. Additionally, the sensor also presents relatively small hysteresis and long-term stability. For low RH levels, the protonic conductor is dominant, whereas for increasing RH levels the ionic contribution becomes prevalent. This study demonstrates that Al2O3 nanotubes have promising applications in environmental monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c0jm02753g

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Cheng, B., Tian, B., Xie, C., Xiao, Y., & Lei, S.
Venue
J. Mater. Chem.
Published
2011
Volume
21
Issue
6
Pages
1907-1912
ISSN
  • 0959-9428 (ISSN-L)
  • 1364-5501
OpenAlex
W2007973004
Cited by
142
References
1
FWCI
4.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.