Design, modeling and characterization of microfluidic architectures for high flow rate, small footprint microfluidic systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We propose a strategy for optimizing distribution of flow in a microfluidic chamber for microreactor, lateral flow assay and immunocapture applications. It is aimed at maximizing flow throughput, while keeping footprint, cell thickness, and shear stress in the distribution channels at a minimum, and offering a uniform flow field along the whole analysis chamber. In order to minimize footprint, the traditional tree-like or "rhombus" design, in which distribution microchannels undergo a series of splittings into two subchannels with equal lengths and widths, was replaced by a design in which subchannel lengths are unequal, and widths are analytically adapted within the Hele-Shaw approximation, in order to keep the flow resistance uniform along all flow paths. The design was validated by hydrodynamic flow simulation using COMSOL finite element software. Simulations show that, if the channel is too narrow, the Hele-Shaw approximation loses accuracy, and the flow velocity in the chamber can fluctuate by up to 20%. We thus used COMSOL simulation to fine-tune the channel parameters, and obtained a fluctuation of flow velocity across the whole chamber below 10%. The design was then implemented into a PDMS device, and flow profiles were measured experimentally using particle tracking. Finally, we show that this system can be applied to cell sorting in self-assembling magnetic arrays, increasing flow throughput by a factor 100 as compared to earlier reported designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Cited by
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Jackson, J. M., Witek, M. A., Kamande, J. W., & Soper, S. A. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00016b · Cited by 172
Human‐on‐Leaf‐Chip: A Biomimetic Vascular System Integrated with Chamber‐Specific Organs
Mao, M., Bei, H. P., Lam, C. H., Chen, P., Wang, S., Chen, Y., He, J., & Zhao, X. (2020) · Small · doi:10.1002/smll.202000546 · Cited by 71
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Cell Migration Assays and Their Application to Wound Healing Assays—A Critical Review
Yang, C., Yin, D., Zhang, H., Badea, I., Yang, S.-M., & Zhang, W. (2024) · Micromachines · doi:10.3390/mi15060720 · Cited by 22
“For example, Saias et al. reported a device with a uniformity of 80% and with a tolerance of 10% [54].”
Metadata
- Authors
- Saias, L., Autebert, J., Malaquin, L., & Viovy, J.-L.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 5
- Pages
- 822
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2032868830
- Cited by
- 59
- References
- 1
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.