The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultrasmall near-infrared gold nanoclusters for tumor fluorescence imaging in vivo
Abstract
In this paper, we explore the possibility of using ultrasmall near-infrared (NIR) gold nanoclusters (AuNCs) as novel contrast imaging agents for tumor fluorescence imaging in vivo. The fluorescence imaging signal of the tail vein administrated AuNCs in living organisms can spectrally be well distinguished from the background with maximum emission wavelength at about 710 nm, and the high photostability of AuNCs promises continuous imaging in vivo. The uptake of AuNCs by the reticuloendothelial system is relatively low in comparison with other nanoparticle-based contrast imaging agents due to their ultrasmall hydrodynamic size (∼2.7 nm). Through the body weight change analysis, the results show that the body weight of the mice administrated with AuNCs has not been changed obviously in comparison with that of the control mice injected with PBS. Furthermore, using MDA-MB-45 and Hela tumor xenograft models, in vivo and ex vivo imaging studies show that the ultrasmall NIR AuNCs are able to be highly accumulated in the tumor areas, thanks to the enhanced permeability and retention (EPR) effects. And the tumor-to-background ratio is about 15 for 6 h postinjection. The results indicate that the ultrasmall NIR AuNCs appear as very promising contrast imaging agents for in vivo fluorescence tumor imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Cited by
Ultra-small fluorescent metal nanoclusters: Synthesis and biological applications
Shang, L., Dong, S., & Nienhaus, G. U. (2011) · Nano Today · doi:10.1016/j.nantod.2011.06.004 · Cited by 1,502
Gold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
Sub-nanometre sized metal clusters: from synthetic challenges to the unique property discoveries
Lu, Y., & Chen, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15325d · Cited by 1,152
Fluorescent Gold Nanoclusters: Recent Advances in Sensing and Imaging
Chen, L.-Y., Wang, C.-W., Yuan, Z., & Chang, H.-T. (2015) · Analytical Chemistry · doi:10.1021/ac503636j · Cited by 848
Li, W., Zhang, H., Assaraf, Y. G., Zhao, K., Xu, X., Xie, J., Yang, D.-H., & Chen, Z.-S. (2016) · Drug Resistance Updates · doi:10.1016/j.drup.2016.05.001 · Cited by 673
Metadata
- Authors
- Wu, X., He, X., Wang, K., Xie, C., Zhou, B., & Qing, Z.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 2
- Issue
- 10
- Pages
- 2244
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2056090494
- Cited by
- 355
- References
- 1
- FWCI
- 12.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasmall near-infrared gold nanoclusters for tumor fluorescence imaging in vivo. https://app.cochat.ai/papers/10.1039/c0nr00359j
- The paper
- Wu, X., He, X., Wang, K., Xie, C., Zhou, B., & Qing, Z. (2010). Ultrasmall near-infrared gold nanoclusters for tumor fluorescence imaging in vivo. Nanoscale. https://doi.org/10.1039/c0nr00359j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.