Wearable electrochemical sensors for in situ analysis in marine environments
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The development of wearable screen-printed electrochemical sensors on underwater garments comprised of the synthetic rubber neoprene is reported. These wearable sensors are able to determine the presence of environmental pollutants and security threats in marine environments. Owing to its unique elastic and superhydrophobic morphology, neoprene is an attractive substrate for thick-film electrochemical sensors for aquatic environments and offers high-resolution printing with no apparent defects. The neoprene-based sensor was evaluated for the voltammetric detection of trace heavy metal contaminants and nitroaromatic explosives in seawater samples. We also describe the first example of enzyme (tyrosinase) immobilization on a wearable substrate towards the amperometric biosensing of phenolic contaminants in seawater. Furthermore, the integration of a miniaturized potentiostat directly on the underwater garment is demonstrated. The wearable sensor-potentiostat microsystem provides a visual indication and alert if the levels of harmful contaminants have exceeded a pre-defined threshold. The concept discussed here is well-suited for integration into dry- and wetsuits worn by divers and recreational surfers/swimmers, thereby providing them with the ability to continuously assess their surroundings for environmental contaminants and security hazards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Self-citation
Cited by
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2013) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 696
Self-citationRecent advances in the potential applications of bioinspired superhydrophobic materials
Darmanin, T., & Guittard, F. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta02071e · Cited by 555
Recent developments and applications of screen-printed electrodes in environmental assays—A review
Li, M., Li, Y.-T., Li, D.-W., & Long, Y.-T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.018 · Cited by 550
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Self-citation
Metadata
- Authors
- Malzahn, K., Windmiller, J. R., Valdés-Ramírez, G., Schöning, M. J., & Wang, J.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 136
- Issue
- 14
- Pages
- 2912
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2058339380
- Cited by
- 127
- References
- 1
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable electrochemical sensors for in situ analysis in marine environments. https://app.cochat.ai/papers/10.1039/c1an15193b
- The paper
- Malzahn, K., Windmiller, J. R., Valdés-Ramírez, G., Schöning, M. J., & Wang, J. (2011). Wearable electrochemical sensors for in situ analysis in marine environments. The Analyst. https://doi.org/10.1039/c1an15193b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.