The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Recent advances in the use of ionic liquids for electrochemical sensing
Abstract
Ionic Liquids are salts that are liquid at (or just above) room temperature. They possess several advantageous properties (e.g. high intrinsic conductivity, wide electrochemical windows, low volatility, high thermal stability and good solvating ability), which make them ideal as non-volatile electrolytes in electrochemical sensors. This mini-review article describes the recent uses of ionic liquids in electrochemical sensing applications (covering the last 3 years) in the context of voltammetric sensing at solid/liquid, liquid/liquid interfaces and carbon paste electrodes, as well as their use in gas sensing, ion-selective electrodes, and for detecting biological molecules, explosives and chemical warfare agents. A comment on the future direction and challenges in this field is also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Room-Temperature Ionic Liquids. Solvents for Synthesis and Catalysis
Welton, T. (1999) · Chemical Reviews · doi:10.1021/cr980032t · Cited by 11,852
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Applications of ionic liquids in the chemical industry
Plechkova, N. V., & Seddon, K. R. (2008) · Chem. Soc. Rev. · doi:10.1039/b006677j · Cited by 5,686
Ionic liquids. Green solvents for the future
Earle, M. J., & Seddon, K. R. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072071391 · Cited by 2,811
van Rantwijk, F., & Sheldon, R. A. (2007) · Chemical Reviews · doi:10.1021/cr050946x · Cited by 1,561
Non‐Haloaluminate Room‐Temperature Ionic Liquids in Electrochemistry—A Review
Buzzeo, M. C., Evans, R. G., & Compton, R. G. (2004) · ChemPhysChem · doi:10.1002/cphc.200301017 · Cited by 1,186
Electrochemical Reactivity in Room-Temperature Ionic Liquids
Hapiot, P., & Lagrost, C. (2008) · Chemical Reviews · doi:10.1021/cr0680686 · Cited by 1,185
Ionic liquids: solvent properties and organic reactivity
Chiappe, C., & Pieraccini, D. (2005) · Journal of Physical Organic Chemistry · doi:10.1002/poc.863 · Cited by 1,169
Air and water stable ionic liquids in physical chemistry
Endres, F., & Zein El Abedin, S. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b600519p · Cited by 1,134
Properties of ionic liquid solvents for catalysis
Wilkes, J. (2004) · Journal of Molecular Catalysis A: Chemical · doi:10.1016/j.molcata.2003.11.029 · Cited by 800
Analytical applications of room-temperature ionic liquids: A review of recent efforts
Pandey, S. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.06.038 · Cited by 756
Sheldon, R. A., Lau, R. M., Sorgedrager, M. J., van Rantwijk, F., & Seddon, K. R. (2002) · Green Chemistry · doi:10.1039/b110008b · Cited by 737
Applications of ionic liquids in electrochemical sensors
Wei, D., & Ivaska, A. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.011 · Cited by 714
A New Ionic Liquid Electrolyte Enhances the Conversion Efficiency of Dye-Sensitized Solar Cells
Wang, P., Zakeeruddin, S. M., Moser, J.-E., & Grätzel, M. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp0355399 · Cited by 625
Chowdhury, S., Mohan, R. S., & Scott, J. L. (2007) · Tetrahedron · doi:10.1016/j.tet.2006.11.001 · Cited by 593
An analytical view of ionic liquids
Baker, G. A., Baker, S. N., Pandey, S., & Bright, F. V. (2005) · The Analyst · doi:10.1039/b500865b · Cited by 434
Application of ionic liquids in electrochemical sensing systems
Shiddiky, M. J. A., & Torriero, A. A. J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.064 · Cited by 408
Use of Room Temperature Ionic Liquids in Gas Sensor Design
Buzzeo, M. C., Hardacre, C., & Compton, R. G. (2004) · Analytical Chemistry · doi:10.1021/ac040042w · Cited by 397
Samec, Z. (2004) · Pure and Applied Chemistry · doi:10.1351/pac200476122147 · Cited by 366
Electrochemistry in Room Temperature Ionic Liquids: A Review and Some Possible Applications
Silvester, D. S., & Compton, R. G. (2006) · Zeitschrift für Physikalische Chemie · doi:10.1524/zpch.2006.220.10.1247 · Cited by 333
Self-citationRoom temperature dialkylimidazolium ionic liquid-based fuel cells
de Souza, R. F., Padilha, J. C., Gonçalves, R. S., & Dupont, J. (2003) · Electrochemistry Communications · doi:10.1016/s1388-2481(03)00173-5 · Cited by 328
Application of Low-Viscosity Ionic Liquid to the Electrolyte of Double-Layer Capacitors
Ue, M., Takeda, M., Toriumi, A., Kominato, A., Hagiwara, R., & Ito, Y. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1559069 · Cited by 326
Barrosse‐Antle, L. E., Bond, A. M., Compton, R. G., O'Mahony, A. M., Rogers, E. I., & Silvester, D. S. (2010) · Chemistry – An Asian Journal · doi:10.1002/asia.200900191 · Cited by 312
Self-citationCarbon Nanotube−Ionic Liquid Composite Sensors and Biosensors
Kachoosangi, R. T., Musameh, M. M., Abu-Yousef, I., Yousef, J. M., Kanan, S. M., Xiao, L., Davies, S. G., Russell, A., & Compton, R. G. (2009) · Analytical Chemistry · doi:10.1021/ac801853r · Cited by 267
Carbon–ionic liquid double-layer capacitors
Lewandowski, A., & Galiński, M. (2004) · Journal of Physics and Chemistry of Solids · doi:10.1016/j.jpcs.2003.09.009 · Cited by 258
Rogers, E. I., Silvester, D. S., Poole, D. L., Aldous, L., Hardacre, C., & Compton, R. G. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp710134e · Cited by 247
Self-citationWang, Y., Zaghib, K., Guerfi, A., Bazito, F. F. C., Torresi, R. M., & Dahn, J. R. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.04.067 · Cited by 201
McEwen, A. B., McDevitt, S. F., & Koch, V. R. (1997) · Journal of The Electrochemical Society · doi:10.1149/1.1837561 · Cited by 199
A Hybrid Electrochemical−Colorimetric Sensing Platform for Detection of Explosives
Forzani, E., Lu, D., Leright, M. J., Aguilar, A. D., Tsow, F., Iglesias, R. A., Zhang, Q. Y., Lü, J., Li, J., & Tao, N. J. (2009) · Journal of the American Chemical Society · doi:10.1021/ja809104h · Cited by 156
A Hybrid Nanosensor for TNT Vapor Detection
Aguilar, A. D., Forzani, E., Leright, M., Tsow, F., Cagan, A. A., Iglesias, R. A., Nagahara, L. A., Amlani, I., Tsui, R. K., & Tao, N. J. (2009) · Nano Letters · doi:10.1021/nl902382s · Cited by 154
Electrochemical Sensing of Ethylene Employing a Thin Ionic-Liquid Layer
Zevenbergen, M. A. G., Wouters, D., Dam, V.-A. T., Brongersma, S. H., & Crego‐Calama, M. (2011) · Analytical Chemistry · doi:10.1021/ac2009756 · Cited by 115
Preparation of all solid-state potentiometric ion sensors with polymer-CNT composites
Zhu, J., Qin, Y., & Zhang, Y. (2009) · Electrochemistry Communications · doi:10.1016/j.elecom.2009.06.025 · Cited by 98
Highly Sensitive Nitric Oxide Sensing Using Three‐Dimensional Graphene/Ionic Liquid Nanocomposite
Ng, S. R., Guo, C., & Li, C. M. (2010) · Electroanalysis · doi:10.1002/elan.201000344 · Cited by 87
Kakiuchi, T., & Tsujioka, N. (2003) · Electrochemistry Communications · doi:10.1016/s1388-2481(03)00039-0 · Cited by 67
Huang, J., & Lin, B.-T. (2009) · The Analyst · doi:10.1039/b910282e · Cited by 64
Jayawardhana, D. A., Crank, J. A., Zhao, Q., Armstrong, D. W., & Guan, X. (2008) · Analytical Chemistry · doi:10.1021/ac801877g · Cited by 54
Langmaier, J., & Samec, Z. (2009) · Analytical Chemistry · doi:10.1021/ac9008258 · Cited by 51
Peng, B., Zhu, J., Liu, X., & Qin, Y. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.02.027 · Cited by 47
Barnes, E. O., O’Mahony, A., Aldous, L., Hardacre, C., & Compton, R. G. (2009) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2009.11.016 · Cited by 26
Shen, X. Q., Chen, X., Liu, J., & Huang, X. (2009) · Journal of Materials Chemistry · doi:10.1039/b914161h · Cited by 13
Cited by
Ionic Liquids at Electrified Interfaces
Fedorov, M. V., & Kornyshev, A. A. (2014) · Chemical Reviews · doi:10.1021/cr400374x · Cited by 1,398
Energetic Ionic Liquids as Explosives and Propellant Fuels: A New Journey of Ionic Liquid Chemistry
Zhang, Q., & Shreeve, J. M. (2014) · Chemical Reviews · doi:10.1021/cr500364t · Cited by 629
Ionic Liquids in Analytical Chemistry: Fundamentals, Advances, and Perspectives
Ho, T. D., Zhang, C., Hantao, L. W., & Anderson, J. L. (2014) · Analytical Chemistry · doi:10.1021/ac4035554 · Cited by 487
Jandera, P., & Janás, P. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.060 · Cited by 309
Metadata
- Authors
- Silvester, D. S.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 136
- Issue
- 23
- Pages
- 4871
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1974842171
- Cited by
- 279
- References
- 41
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.