The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A differentially selective sensor with fluorescence turn-on response to Zn2+and dual-mode ratiometric response to Al3+in aqueous media
Abstract
A novel quinoline-coumarin (QC) fluoroionophore conjugated by means of a triazolyl-pyrrolidinyl linker exhibits differential dual selectivity for Zn(2+) and Al(3+) in mixed media. QC acts as a turn on fluorescence sensor for Zn(2+) while exhibiting overall ratiometric selectivity for Al(3+) in aqueous media. Moreover, QC exhibited preferential second mode of selectivity for Al(3+) as it ratiometrically displaces Zn(2+) from the [QC + Zn(2+)] complex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aluminum Toxicity and Tolerance in Plants
Delhaize, E., & Ryan, P. R. (1995) · Plant Physiology · doi:10.1104/pp.107.2.315 · Cited by 1,346
Zhang, J. F., Zhou, Y., Yoon, J., & Kim, J. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15028f · Cited by 826
Xu, Z., Baek, K.-H., Kim, H. N., Cui, J., Qian, X., Spring, D. R., Shin, I., & Yoon, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja907334j · Cited by 692
Chemical sensors that incorporate click-derived triazoles
Lau, Y. H., Rutledge, P. J., Watkinson, M., & Todd, M. H. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00143k · Cited by 407
Pyrrolidine constrained bipyridyl-dansyl click fluoroionophore as selective Al3+sensor
Maity, D., & Govindaraju, T. (2010) · Chemical Communications · doi:10.1039/c0cc00119h · Cited by 346
Self-citationFahrni, C. J., & O'Halloran, T. V. (1999) · Journal of the American Chemical Society · doi:10.1021/ja992709f · Cited by 332
Zhang, J. F., Zhou, Y. M., Yoon, J., Kim, Y., Kim, S. J., & Kim, J. S. (2010) · Organic Letters · doi:10.1021/ol101535s · Cited by 313
Novel Optical/Electrochemical Selective 1,2,3-Triazole Ring-Appended Chemosensor for the Al3+ Ion
Kim, S. H., Choi, H., Kim, J., Lee, S. J., Quang, D. T., & Kim, J. S. (2009) · Organic Letters · doi:10.1021/ol902743s · Cited by 305
Ratiometric Zn2+ Fluorescent Sensor and New Approach for Sensing Cd2+ by Ratiometric Displacement
Xue, L., Liu, Q., & Jiang, H. (2009) · Organic Letters · doi:10.1021/ol901380w · Cited by 284
Aluminum and Alzheimer's disease: model studies
Fasman, G. (1996) · Coordination Chemistry Reviews · doi:10.1016/0010-8545(96)89157-0 · Cited by 277
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Shellaiah, M., Wu, Y.-H., Singh, A., Ramakrishnam Raju, M. V., & Lin, H.-C. (2013) · J. Mater. Chem. A · doi:10.1039/c2ta00574c · Cited by 287
Rajasekhar, K., & Govindaraju, T. (2018) · RSC Advances · doi:10.1039/c8ra03620a · Cited by 150
Self-citationUnambiguous Detection of Elevated Levels of Hypochlorous Acid in Double Transgenic AD Mouse Brain
Samanta, S., & Govindaraju, T. (2019) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.9b00554 · Cited by 57
Self-citation
Metadata
- Authors
- Maity, D., & Govindaraju, T.
- Venue
- Chem. Commun.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 48
- Issue
- 7
- Pages
- 1039-1041
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2167976374
- Cited by
- 330
- References
- 11
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A differentially selective sensor with fluorescence turn-on response to Zn2+and dual-mode ratiometric response to Al3+in aqueous media. https://app.cochat.ai/papers/10.1039/c1cc16064h
- The paper
- Maity, D., & Govindaraju, T. (2012). A differentially selective sensor with fluorescence turn-on response to Zn2+and dual-mode ratiometric response to Al3+in aqueous media. Chem. Commun. https://doi.org/10.1039/c1cc16064h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.