Electrical conductivity, ionic conductivity, optical absorption, and gas separation properties of ionically conductive polymer membranes embedded with Si microwire arrays
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The optical absorption, ionic conductivity, electronic conductivity, and gas separation properties have been evaluated for flexible composite films of ionically conductive polymers that contain partially embedded arrays of ordered, crystalline, p-type Si microwires. The cation exchange ionomer Nafion, and a recently developed anion exchange ionomer, poly(arylene ether sulfone) that contains quaternary ammonium groups (QAPSF), produced composite microwire array/ionomer membrane films that were suitable for operation in acidic or alkaline media, respectively. The ionic conductivity of the Si wire array/Nafion composite films in 2.0 M H2SO4(aq) was 71 mS cm−1, and the conductivity of the Si wire array/QAPSF composite films in 2.0 M KOH(aq) was 6.4 mS cm−1. Both values were comparable to the conductivities observed for films of these ionomers that did not contain embedded Si wire arrays. Two Si wire array/Nafion membranes were electrically connected in series, using a conducting polymer, to produce a trilayer, multifunctional membrane that exhibited an ionic conductivity in 2.0 M H2SO4(aq) of 57 mS cm−1 and an ohmic electrical contact, with an areal resistance of ∼0.30 Ω cm2, between the two physically separate embedded Si wire arrays. All of the wire array/ionomer composite membranes showed low rates of hydrogen crossover. Optical measurements indicated very low absorption (<3%) in the ion-exchange polymers but high light absorption (up to 80%) by the wire arrays even at normal incidence, attesting to the suitability of such multifunctional membranes for application in solar fuels production.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639157 · Cited by 462
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Sheng, W., Myint, M., Chen, J. G., & Yan, Y. (2013) · Energy & Environmental Science · doi:10.1039/c3ee00045a · Cited by 1,202
A Fully Integrated Nanosystem of Semiconductor Nanowires for Direct Solar Water Splitting
Liu, C., Tang, J., Chen, H. M., Liu, B., & Yang, P. (2013) · Nano Letters · doi:10.1021/nl401615t · Cited by 549
Molecular Chromophore–Catalyst Assemblies for Solar Fuel Applications
Ashford, D. L., Gish, M. K., Vannucci, A. K., Brennaman, M. K., Templeton, J. L., Papanikolas, J. M., & Meyer, T. J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00229 · Cited by 483
Water‐Splitting Catalysis and Solar Fuel Devices: Artificial Leaves on the Move
Joya, K. S., Joya, Y. F., Ocakoglu, K., & van de Krol, R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201300136 · Cited by 452
Metadata
- Authors
- Spurgeon, J. M., Walter, M. G., Zhou, J., Kohl, P. A., & Lewis, N. S.
- Venue
- Energy & Environmental Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 4
- Issue
- 5
- Pages
- 1772
- ISSN
- 1754-5692 (ISSN-L)
- 1754-5706
- OpenAlex
- W2153442073
- Cited by
- 105
- References
- 1
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.