Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 320

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Carbon nanotube-coated macroporous sponge for microbial fuel cell electrodes

Xie, Xing, Ye, Meng, Hu, Liangbing, Liu, Nian, McDonough, James R., Chen, Wei, Alshareef, H. N., Criddle, Craig S., Cui, Yi · 2012 · Energy Environ. Sci.

Abstract

The materials that are used to make electrodes and their internal structures significantly affect microbial fuel cell (MFC) performance. In this study, we describe a carbon nanotube (CNT)–sponge composite prepared by coating a sponge with CNTs. Compared to the CNT-coated textile electrodes evaluated in prior studies, CNT–sponge electrodes had lower internal resistance, greater stability, more tunable and uniform macroporous structure (pores up to 1 mm in diameter), and improved mechanical properties. The CNT–sponge composite also provided a three-dimensional scaffold that was favorable for microbial colonization and catalytic decoration. Using a batch-fed H-shaped MFC outfitted with CNT–sponge electrodes, an areal power density of 1.24 W m−2 was achieved when treating domestic wastewater. The maximum volumetric power density of a continuously fed plate-shaped MFC was 182 W m−3. To our knowledge, these are the highest values obtained to date for MFCs fed domestic wastewater: 2.5 times the previously reported maximum areal power density and 12 times the previously reported maximum volumetric power density.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c1ee02122b

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 13

  1. Konikoff, 1963, Aerosp. Med., 34, 1129
  2. Wilkinson, 2000, Auton. Rob., 9, 99, 10.1023/A:1008984516499 · doi:10.1023/a:1008984516499
  3. Tsai, 2009, J. Power Sources, 194, 199, 10.1016/j.jpowsour.2009.05.018 · doi:10.1016/j.jpowsour.2009.05.018
  4. Zhao, 2010, Chem.–Eur. J., 16, 4982, 10.1002/chem.200903486 · doi:10.1002/chem.200903486
  5. Sun, 2010, Biosens. Bioelectron., 26, 338, 10.1016/j.bios.2010.08.010 · doi:10.1016/j.bios.2010.08.010
  6. Qiao, 2008, ACS Nano, 2, 113, 10.1021/nn700102s · doi:10.1021/nn700102s
  7. Qiao, 2007, J. Power Sources, 170, 79, 10.1016/j.jpowsour.2007.03.048 · doi:10.1016/j.jpowsour.2007.03.048
  8. Aelterman, 2009, Electrochim. Acta, 54, 5754, 10.1016/j.electacta.2009.05.023 · doi:10.1016/j.electacta.2009.05.023
  9. Kim, 2011, Bioresour. Technol., 102, 342, 10.1016/j.biortech.2010.07.005 · doi:10.1016/j.biortech.2010.07.005
  10. Hertel, 1998, Phys. Rev. B: Condens. Matter, 58, 13870, 10.1103/PhysRevB.58.13870 · doi:10.1103/physrevb.58.13870
  11. Ahn, 2010, Bioresour. Technol., 101, 469, 10.1016/j.biortech.2009.07.039 · doi:10.1016/j.biortech.2009.07.039
  12. You, 2006, Chem. Biochem. Eng. Q., 20, 407
  13. Jiang, 2011, Int. J. Hydrogen Energy, 36, 876, 10.1016/j.ijhydene.2010.08.074 · doi:10.1016/j.ijhydene.2010.08.074

Cited by

See all 320

Metadata

Authors
Xie, X., Ye, M., Hu, L., Liu, N., McDonough, J. R., Chen, W., Alshareef, H. N., Criddle, C. S., & Cui, Y.
Venue
Energy Environ. Sci.
Published
2012
Volume
5
Issue
1
Pages
5265-5270
ISSN
  • 1754-5692 (ISSN-L)
  • 1754-5706
OpenAlex
W2139851407
Cited by
320
References
30
FWCI
17.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.