The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Patterning the differentiation of C2C12 skeletal myoblasts
Abstract
Mammalian cells are sensitive to the physical properties of their micro-environment such as the stiffness and geometry of the substrate. It is known that the stiffness of the substrate plays a key role in the process of mammalian myogenesis. However, the effect of geometrical constraints on the process of myogenic differentiation needs to be explored further. Here, we show that the geometrical cues of substrates can significantly influence the differentiation process of C2C12 skeletal myoblasts. Three different geometries including lines of different widths, tori of different inner diameters, and hybrid structures (linear and circular features with different arc degrees) were created by micro-contact printing of fibronectin on the surface of Petri dishes. The differentiation of C2C12 cells was studied over a period of seven days and was quantified; we report the differentiation parameters of (1) fusion index, (2) degree of maturation, (3) alignment, and (4) response to electrical pulse stimulation (EPS). Hybrid structures with the smallest arc degree (hybrid 30°) showed the best results for all four differentiation parameters. The hybrid 30° pattern exhibits an ~2-fold increase in the fusion index when compared to the line patterns and an ~3-fold increase when compared to the toroid patterns. The hybrid 30° also showed a higher maturation index compared to the line or the toroid patterns. In response to electrical stimulation (20 V, 50 ms pulse, 1 Hz), mature myotubes on hybrid 30° patterns showed an ~2-fold increase in cellular displacement when compared to myotubes on the line and torus patterns. We tested the influence of C2C12 cell density on fusion and maturation indices, and the results suggest that density does not exert significant influence on cellular differentiation under these conditions. Our results can have important implications in engineering skeletal muscle tissues and designing muscle cell bio-actuators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Local force and geometry sensing regulate cell functions
Vogel, V., & Sheetz, M. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1890 · Cited by 2,328
Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325
Geometric cues for directing the differentiation of mesenchymal stem cells
Kilian, K. A., Bugarija, B., Lahn, B. T., & Mrksich, M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903269107 · Cited by 1,841
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765
Yoshida, N., Yoshida, S., Koishi, K., Masuda, K., & Nabeshima, Y.-I. (1998) · Journal of Cell Science · doi:10.1242/jcs.111.6.769 · Cited by 425
The role of cardiac tissue alignment in modulating electrical function
CHUNG, C., BIEN, H., & ENTCHEVA, E. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00959.x · Cited by 74
Cited by
3D biofabrication strategies for tissue engineering and regenerative medicine
Bajaj, P., Schweller, R. M., Khademhosseini, A., West, J. L., & Bashir, R. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105155 · Cited by 632
Self-citationThree-dimensionally printed biological machines powered by skeletal muscle
Cvetkovic, C., Raman, R., Chan, V., Williams, B. J., Tolish, M., Bajaj, P., Sakar, M. S., Asada, H. H., Saif, M. T. A., & Bashir, R. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1401577111 · Cited by 443
Self-citationChen, M.-C., Sun, Y.-C., & Chen, Y.-H. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.024 · Cited by 392
Skeletal muscle tissue engineering: methods to form skeletal myotubes and their applications
Ostrovidov, S., Hosseini, V., Ahadian, S., Fujie, T., Parthiban, S. P., Ramalingam, M., Bae, H., Kaji, H., & Khademhosseini, A. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2013.0534 · Cited by 302
“showed that the geometrical cues of a substrate significantly affect myoblast differentiation.(84) They cultured C2C12 cells on dishes with different geometrical fibronectin coatings for 1 week and observed that myotubes with a hybrid line-torus shape had a two- and threefold increase in their fusion index when compar…”
InfluentialMyoblast differentiation on graphene oxide
Ku, S. H., & Park, C. B. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.052 · Cited by 259
Metadata
- Authors
- Bajaj, P., Reddy, B., Millet, L., Wei, C., Zorlutuna, P., Bao, G., & Bashir, R.
- Venue
- Integrative Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 2011
- Volume
- 3
- Issue
- 9
- Pages
- 897
- ISSN
- 1757-9694 (ISSN-L)
- 1757-9708
- OpenAlex
- W1983740089
- Cited by
- 212
- References
- 8
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.