The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Assembly of Ni(OH)2 nanoplates on reduced graphene oxide: a two dimensional nanocomposite for enzyme-free glucose sensing
Abstract
Ni(OH)2 nanoplates were successfully synthesized and in situ assembled on reduced graphene oxide (RGO) nanosheets by a simple one-pot method. This RGO-Ni(OH)2 nanocomposite was characterized by transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), X-ray powder diffraction (XRD), Raman and X-ray photoelectron spectroscopy (XPS). TEM images showed that the composite was round and that leaf-shaped nanoplates with a diameter of about 150 nm assembled on the RGO nanosheets. EDX, XRD, Raman and XPS characterization proved that the constituent parts of the composite were Ni(OH)2 and RGO. Moreover, the amount of Ni(OH)2 assembled on the RGO could be adjusted simply by changing the volume of NiCl2 added to the reactant mixture. For the strong catalytic ability of the high-valent oxydroxide species (NiOOH) formed in alkaline media, the RGO-Ni(OH)2 nanocomposite was used as the matrix for the non-enzymatic detection of glucose. A low detection limit of 0.6 μM with a wide linear range from 2 μM to 3.1 mM (R = 0.9987) could be obtained. The operating simplicity and low expense of fabrication make this Ni(OH)2-based electrode attractive in sensor construction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geim, A. K., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1849 · Cited by 39,979
Synthesis of graphene-based nanosheets via chemical reduction of exfoliated graphite oxide
Stankovich, S., Dikin, D. A., Piner, R. D., Kohlhaas, K. A., Kleinhammes, A., Jia, Y., Wu, Y., Nguyen, S. T., & Ruoff, R. S. (2007) · Carbon · doi:10.1016/j.carbon.2007.02.034 · Cited by 13,878
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Processable aqueous dispersions of graphene nanosheets
Li, D., Müller, M. B., Gilje, S., Kaner, R. B., & Wallace, G. G. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2007.451 · Cited by 9,114
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Ni(OH) 2 Nanoplates Grown on Graphene as Advanced Electrochemical Pseudocapacitor Materials
Wang, H., Casalongue, H. S., Liang, Y., & Dai, H. (2010) · Journal of the American Chemical Society · doi:10.1021/ja102267j · Cited by 2,042
Guo, S., Dong, S., & Wang, E. (2010) · ACS Nano · doi:10.1021/nn9014483 · Cited by 1,170
Functional Composite Materials Based on Chemically Converted Graphene
Bai, H., Li, C., & Shi, G. (2011) · Advanced Materials · doi:10.1002/adma.201003753 · Cited by 1,080
Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes
Musameh, M., Wang, J., Merkoci, A., & Lin, Y. (2002) · Electrochemistry Communications · doi:10.1016/s1388-2481(02)00451-4 · Cited by 1,066
Tung, V. C., Chen, L.-M., Allen, M. J., Wassei, J. K., Nelson, K., Kaner, R. B., & Yang, Y. (2009) · Nano Letters · doi:10.1021/nl9001525 · Cited by 1,010
Cited by
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Electrochemical non-enzymatic glucose sensors: recent progress and perspectives
Wei, M., Qiao, Y., Zhao, H., Liang, J., Li, T., Luo, Y., Lu, S., Shi, X., Lu, W., & Sun, X. (2020) · Chemical Communications · doi:10.1039/d0cc05650b · Cited by 467
Niu, X., Lan, M., Zhao, H., & Chen, C. (2013) · Analytical Chemistry · doi:10.1021/ac3030976 · Cited by 412
Nanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Huo, H., Zhao, Y., & Xu, C. (2014) · Journal of Materials Chemistry A · doi:10.1039/c4ta02857k · Cited by 357
Recent Advances in Flexible/Stretchable Supercapacitors for Wearable Electronics
Li, L., Lou, Z., Chen, D., Jiang, K., Han, W., & Shen, G. (2018) · Small · doi:10.1002/smll.201702829 · Cited by 297
Nanocomposites and macroscopic materials: assembly of chemically modified graphene sheets
Wu, D., Zhang, F., Liang, H., & Feng, X. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35179j · Cited by 296
Yang, J., Duan, X., Guo, W., Li, D., Zhang, H., & Zheng, W. (2014) · Nano Energy · doi:10.1016/j.nanoen.2014.02.006 · Cited by 288
Nonenzymatic glucose sensor based on graphene oxide and electrospun NiO nanofibers
Zhang, Y., Wang, Y., Jia, J., & Wang, J. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.05.037 · Cited by 254
Self-citationBaşkaya, G., Yıldız, Y., Savk, A., Okyay, T. O., Eriş, S., Sert, H., & Şen, F. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.045 · Cited by 156
RetractedKundu, M. K., Sadhukhan, M., & Barman, S. (2015) · Journal of Materials Chemistry B · doi:10.1039/c4tb01740d · Cited by 54
Metadata
- Authors
- Zhang, Y., Xu, F., Sun, Y., Shi, Y., Wen, Z., & Li, Z.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 21
- Issue
- 42
- Pages
- 16949
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2014790953
- Cited by
- 252
- References
- 31
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.