The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Highly Sensitive and Selective Nonenzymatic Detection of Glucose Using Three-Dimensional Porous Nickel Nanostructures
Abstract
Highly sensitive and selective nonenzymatic detection of glucose has been achieved using a novel disposable electrochemical sensor based on three-dimensional (3D) porous nickel nanostructures. The enzyme-free sensor was fabricated through in situ growing porous nickel networks on a homemade screen-printed carbon electrode substrate via electrochemically reducing the Ni(2+) precursor, along with continuously liberating hydrogen bubbles. The resulting nickel-modified electrode was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectrometry (EDX), powder X-ray diffractometry (XRD), and electrochemical techniques. Cyclic voltammetric, alternating-current impedance, and amperometric methods were used to investigate the catalytic properties of the assembled sensor for glucose electro-oxidation in alkaline media. Under optimized conditions, the enzymeless sensor exhibited excellent performance for glucose analysis selectively, offering a much wider linear range (from 0.5 μM to 4 mM), an extremely low detection limit (0.07 μM, signal-to-noise ratio (S/N) of 3), and an ultrahigh sensitivity of 2.9 mA/(cm(2) mM). Importantly, favorable reproducibility and long-term performance stability were obtained thanks to the robust frameworks. Application of the proposed sensor in monitoring blood glucose was also demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40
Wu, X., Bao, C., Niu, Q., & Lu, W. (2019) · Nanotechnology · doi:10.1088/1361-6528/aafe53 · Cited by 28
Metadata
- Authors
- Niu, X., Lan, M., Zhao, H., & Chen, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-03-15
- Volume
- 85
- Issue
- 7
- Pages
- 3561-3569
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1983821901
- Cited by
- 412
- References
- 4
- FWCI
- 24.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Selective Nonenzymatic Detection of Glucose Using Three-Dimensional Porous Nickel Nanostructures. https://app.cochat.ai/papers/10.1021/ac3030976
- The paper
- Niu, X., Lan, M., Zhao, H., & Chen, C. (2013). Highly Sensitive and Selective Nonenzymatic Detection of Glucose Using Three-Dimensional Porous Nickel Nanostructures. Analytical Chemistry. https://doi.org/10.1021/ac3030976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.