The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Double-emulsion drops with ultra-thin shells for capsule templates
Abstract
We introduce an emulsification technique that creates monodisperse double-emulsion drops with a core-shell geometry having an ultra-thin wall as a middle layer. We create a biphasic flow in a microfluidic capillary device by forming a sheath flow consisting of a thin layer of a fluid with high affinity to the capillary wall flowing along the inner wall of the capillary, surrounding the innermost fluid. This creates double-emulsion drops, using a single-step emulsification, having a very thin fluid shell. If the shell is solidified, its thickness can be small as a hundred nanometres or even less. Despite the small thickness of this shell, these structures are nevertheless very stable, giving them great potential for encapsulation. We demonstrate this by creating biodegradable microcapsules of poly(lactic acid) with a shell thickness of a few tens of nanometres, which are potentially useful for encapsulation and delivery of drugs, cosmetics, and nutrients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
Cited by
Microfluidic fabrication of microparticles for biomedical applications
Li, W., Zhang, L., Ge, X., Xu, B., Zhang, W., Qu, L., Choi, C.-H., Xu, J., Zhang, A., Lee, H., et al. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00263g · Cited by 585
Self-citationMultiphase flow microfluidics for the production of single or multiple emulsions for drug delivery
Zhao, C.-X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.009 · Cited by 451
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Full‐Spectrum Photonic Pigments with Non‐iridescent Structural Colors through Colloidal Assembly
Park, J., Kim, S., Magkiriadou, S., Choi, T. M., Kim, Y., & Manoharan, V. N. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201309306 · Cited by 257
Self-citationDevelopment and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
Self-citation
Metadata
- Authors
- Kim, S.-H., Kim, J. W., Cho, J.-C., & Weitz, D. A.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 18
- Pages
- 3162-3166
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2113743625
- Cited by
- 259
- References
- 1
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Double-emulsion drops with ultra-thin shells for capsule templates. https://app.cochat.ai/papers/10.1039/c1lc20434c
- The paper
- Kim, S.-H., Kim, J. W., Cho, J.-C., & Weitz, D. A. (2011). Double-emulsion drops with ultra-thin shells for capsule templates. Lab Chip. https://doi.org/10.1039/c1lc20434c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.