The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemical determination of glutathione: a review
Abstract
The physiological importance of glutathione and glutathione disulfide is evident from their implications in an array of medical conditions including diabetes, Parkinson's disease and cancer. As such the need for simple, rapid and cheap assays to aid clinical diagnostics and treatment is clear. These requirements are, in principle at least, ideally suited to electrochemical detection. Accordingly a large array of voltammetric methods ultimately aimed at making cheap and most likely disposable electrodes have been reported. This critical review analyses the context in which physiological glutathione measurement can be undertaken electrochemically and compares it to current assay approaches, while also covering the current literature for glutathione disulfide detection. The various characteristics and limitations of the methodologies are compared and contrasted, with the analytical parameters (matrix, pH, limit of detection, etc.) tabulated to aid comparison.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pinnen, F., Sozio, P., Cacciatore, I., Cornacchia, C., Mollica, A., Iannitelli, A., D′Aurizio, E., Cataldi, A., Zara, S., Nasuti, C., et al. (2011) · Archiv der Pharmazie · doi:10.1002/ardp.201000209 · Cited by 49
Cited by
Quantification of thiols and disulfides
Winther, J. R., & Thorpe, C. (2014) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.03.031 · Cited by 385
Metal–organic framework composites as electrocatalysts for electrochemical sensing applications
Kempahanumakkagari, S., Vellingiri, K., Deep, A., Kwon, E. E., Bolan, N., & Kim, K.-H. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.028 · Cited by 370
Cai, Q.-Y., Li, J., Ge, J., Zhang, L., Hu, Y.-L., Li, Z.-H., & Qu, L.-B. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.04.077 · Cited by 346
Qu, H., Fan, C., Chen, M., Zhang, X., Yan, Q., Wang, Y., Zhang, S., Gong, Z., Shi, L., Li, X., et al. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-021-01149-z · Cited by 306
Metadata
- Authors
- Harfield, J. C., Batchelor-McAuley, C., & Compton, R. G.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 137
- Issue
- 10
- Pages
- 2285
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2076742493
- Cited by
- 222
- References
- 1
- FWCI
- 10.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical determination of glutathione: a review. https://app.cochat.ai/papers/10.1039/c2an35090d
- The paper
- Harfield, J. C., Batchelor-McAuley, C., & Compton, R. G. (2012). Electrochemical determination of glutathione: a review. The Analyst. https://doi.org/10.1039/c2an35090d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.