Detection of SERS active labelled DNA based on surface affinity to silver nanoparticles
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Developments in specific DNA detection assays have been shown to be increasingly beneficial for molecular diagnostics and biological research. Many approaches use optical spectroscopy as an assay detection method and, owing to the sensitivity and molecular specificity offered, surface enhanced Raman scattering (SERS) spectroscopy has become a competitively exploited technique. This study utilises SERS to demonstrate differences in affinity of dye labelled DNA through differences in electrostatic interactions with silver nanoparticles. Results show clear differences in the SERS intensity obtained from single stranded DNA, double stranded DNA and a free dye label and demonstrate surface attraction is driven through electrostatic charges on the nucleotides and not the SERS dye. It has been further demonstrated that, through optimisation of experimental conditions and careful consideration of sequence composition, a DNA detection method with increased sample discrimination at lower DNA concentrations can be achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, S., & Kimura, K. (1999) · Langmuir · doi:10.1021/la9812828 · Cited by 362
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Silver nanoparticles in the environment
Yu, S.-J., Yin, Y.-G., & Liu, J.-F. (2013) · Environ. Sci.: Processes Impacts · doi:10.1039/c2em30595j · Cited by 456
Multiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Self-citationReview of Surface Enhanced Raman Scattering Applications in Forensic Science
Muehlethaler, C., Leona, M., & Lombardi, J. R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04131 · Cited by 313
Isolation and identification of bacteria by means of Raman spectroscopy
Pahlow, S., Meisel, S., Cialla-May, D., Weber, K., Rösch, P., & Popp, J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.006 · Cited by 308
Nanotechnology-Enhanced No-Wash Biosensors for in Vitro Diagnostics of Cancer
Huang, X., Liu, Y., Yung, B., Xiong, Y., & Chen, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b02618 · Cited by 259
Surface-enhanced Raman spectroscopy for bioanalysis and diagnosis
Tahir, M. A., Dina, N. E., Cheng, H., Valev, V. K., & Zhang, L. (2021) · Nanoscale · doi:10.1039/d1nr00708d · Cited by 257
Simultaneous detection and quantification of three bacterial meningitis pathogens by SERS
Gracie, K., Correa, E., Mabbott, S., Dougan, J. A., Graham, D., Goodacre, R., & Faulds, K. (2014) · Chem. Sci. · doi:10.1039/c3sc52875h · Cited by 161
Self-citationNgo, H. T., Freedman, E., Odion, R. A., Strobbia, P., De Silva Indrasekara, A. S., Vohra, P., Taylor, S. M., & Vo-Dinh, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-21615-3 · Cited by 66
Metadata
- Authors
- Harper, M. M., Dougan, J. A., Shand, N. C., Graham, D., & Faulds, K.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 137
- Issue
- 9
- Pages
- 2063
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2125117409
- Cited by
- 42
- References
- 1
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.