Direct Detection of Unamplified Pathogen RNA in Blood Lysate using an Integrated Lab-in-a-Stick Device and Ultrabright SERS Nanorattles
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Direct detection of genetic biomarkers in body fluid lysate without target amplification will revolutionize nucleic acid-based diagnostics. However, the low concentration of target sequences makes this goal challenging. We report a method for direct detection of pathogen RNA in blood lysate using a bioassay using surface-enhanced Raman spectroscopy (SERS)-based detection integrated in a “lab-in-a-stick” portable device. Two levels of signal enhancement were employed to achieve the sensitivity required for direct detection. Each target sequence was tagged with an ultrabright SERS-encoded nanorattle with ultrahigh SERS signals, and these tagged target sequences were concentrated into a focused spot for detection using hybridization sandwiches with magnetic microbeads. Furthermore, the washing process was automated by integration into a “lab-in-a-stick” portable device. We could directly detect synthetic target with a limit of detection of 200 fM. More importantly, we detected plasmodium falciparum malaria parasite RNA directly in infected red blood cells lysate. To our knowledge, this is the first report of SERS-based direct detection of pathogen nucleic acid in blood lysate without nucleic acid extraction or target amplification. The results show the potential of our integrated bioassay for field use and point-of-care diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Nanorattles have been used for the direct detection of malaria DNA in blood lysate[ 18 ] and the detection of a squamous cell carcinoma mRNA biomarker in unamplified RNA extracts from head and neck cancer tissue.[ 19 , 20 ]”
From Machine learning using convolutional neural networks for SERS analysis of biomarkers in medical diagnostics (2022) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Human Malaria Parasites in Continuous Culture
Trager, W., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,844
Single Molecule Detection Using Surface-Enhanced Raman Scattering (SERS)
Kneipp, K., Wang, Y., Kneipp, H., Perelman, L. T., Itzkan, I., Dasari, R. R., & Feld, M. S. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1667 · Cited by 6,816
Nanoparticles with Raman Spectroscopic Fingerprints for DNA and RNA Detection
Cao, Y. C., Jin, R., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.297.5586.1536 · Cited by 2,971
Surface‐Enhanced Raman Spectroscopy: Concepts and Chemical Applications
Schlücker, S. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201205748 · Cited by 2,417
Gold Nanocages: Synthesis, Properties, and Applications
Skrabalak, S. E., Chen, J., Sun, Y., Lu, X., Au, L., Cobley, C. M., & Xia, Y. (2008) · Accounts of Chemical Research · doi:10.1021/ar800018v · Cited by 1,447
Xia, X., Wang, Y., Ruditskiy, A., & Xia, Y. (2013) · Advanced Materials · doi:10.1002/adma.201302820 · Cited by 1,019
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Point-of-care nucleic acid testing for infectious diseases
Niemz, A., Ferguson, T. M., & Boyle, D. S. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.007 · Cited by 838
Hill, H. D., & Mirkin, C. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.51 · Cited by 588
Research works printed but not linked: 1
- D’Agata, R. et al. Detection of genomic disorders in unamplified human genomic DNA using an ultrasensitive surface plasmon resonance imaging method. Int J Mol Med 28, S59–S59 (2011).
Cited by
Present and Future of Surface-Enhanced Raman Scattering
Langer, J., Jimenez de Aberasturi, D., Aizpurua, J., Alvarez-Puebla, R. A., Auguié, B., Baumberg, J. J., Bazan, G. C., Bell, S. E. J., Boisen, A., Brolo, A. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b04224 · Cited by 3,880
Self-citationNucleic Acid Tests for Clinical Translation
Li, M., Yin, F., Song, L., Mao, X., Li, F., Fan, C., Zuo, X., & Xia, Q. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00241 · Cited by 264
Perumal, J., Wang, Y., Attia, A. B. E., Dinish, U. S., & Olivo, M. (2021) · Nanoscale · doi:10.1039/d0nr06832b · Cited by 235
Paul, R., Ostermann, E., & Wei, Q. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112592 · Cited by 211
Synthesis, Assembly, Optical Properties, and Sensing Applications of Plasmonic Gap Nanostructures
Kim, J., Lee, C., Lee, Y., Lee, J., Park, S., Park, S., & Nam, J. (2021) · Advanced Materials · doi:10.1002/adma.202006966 · Cited by 140
Metadata
- Authors
- Ngo, H. T., Freedman, E., Odion, R. A., Strobbia, P., De Silva Indrasekara, A. S., Vohra, P., Taylor, S. M., & Vo-Dinh, T.
- Affiliations
- Vietnam National University Ho Chi Minh City (VN)
- Duke University (US)
- Venue
- Scientific Reports
- Published
- 2018-03-06
- Volume
- 8
- Issue
- 1
- Pages
- 4075-4075
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5840326
- OpenAlex
- W2807288497
- Cited by
- 66
- References
- 71
- Citations by year
- 2026: 6 · 2025: 6 · 2024: 6 · 2023: 3 · 2022: 8 · 2021: 10 · 2020: 9 · 2019: 15 · 2018: 3
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Vietnam Education Foundation
- National Institutes of Health
- National Institute of Allergy and Infectious Diseases (K08AI100924, R21AI120981)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Keywords
- surface-enhanced Raman spectroscopy, point-of-care testing, Plasmodium falciparum, malaria, magnetic microbeads, portable diagnostic device
- MeSH terms
- Point-of-Care Testing, Blood Cells, Nucleic Acid Hybridization, Sensitivity and Specificity, Spectrum Analysis, Raman, RNA, Protozoan, Malaria, Falciparum, Molecular Diagnostic Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct Detection of Unamplified Pathogen RNA in Blood Lysate using an Integrated Lab-in-a-Stick Device and Ultrabright SERS Nanorattles. https://app.cochat.ai/papers/10.1038/s41598-018-21615-3
- The paper
- Ngo, H. T., Freedman, E., Odion, R. A., Strobbia, P., De Silva Indrasekara, A. S., Vohra, P., Taylor, S. M., & Vo-Dinh, T. (2018). Direct Detection of Unamplified Pathogen RNA in Blood Lysate using an Integrated Lab-in-a-Stick Device and Ultrabright SERS Nanorattles. Scientific Reports. https://doi.org/10.1038/s41598-018-21615-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.