The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Chemiluminescence biosensors for DNA detection using graphene oxide and a horseradish peroxidase-mimicking DNAzyme
Abstract
In this communication, we demonstrate that graphene oxide (GO) greatly inhibits the peroxidatic activity of a horseradish peroxidase-mimicking DNAzyme. Combining this observation with the unique DNA/GO interactions, an ultrasensitive GO-based chemiluminescence DNA biosensing platform is developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Cited by
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Huang, X., Zeng, Z., Fan, Z., Liu, J., & Zhang, H. (2012) · Advanced Materials · doi:10.1002/adma.201201587 · Cited by 923
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Graphene based sensors and biosensors
Justino, C. I. L., Gomes, A. R., Freitas, A. C., Duarte, A. C., & Rocha-Santos, T. A. P. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.003 · Cited by 574
Xu, Y., Bai, P., Zhou, X., Akimov, Y., Png, C. E., Ang, L., Knoll, W., & Wu, L. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801433 · Cited by 519
Metadata
- Authors
- Luo, M., Chen, X., Zhou, G., Xiang, X., Chen, L., Ji, X., & He, Z.
- Venue
- Chem. Commun.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 48
- Issue
- 8
- Pages
- 1126-1128
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2003213689
- Cited by
- 161
- References
- 1
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.