The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Coumarin-derived transformable fluorescent sensor for Zn2+
Abstract
We report a coumarin-derived fluorescent sensor for Zn(2+) termed CTS. CTS shows excellent binding selectivity for Zn(2+) over competing metal ions due to the transformable ability of CTS, that is the displacement of other metal ions by Zn(2+), which induces transformation of chelation from an amide to an imidic acid tautomeric form.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bush, A. (2000) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(99)00073-3 · Cited by 731
Reprogramming of the immune system during zinc deficiency
Fraker, P. J., & King, L. E. (2004) · Annual Review of Nutrition · doi:10.1146/annurev.nutr.24.012003.132454 · Cited by 470
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Krämer, J., Kang, R., Grimm, L. M., De Cola, L., Picchetti, P., & Biedermann, F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00746 · Cited by 449
Fluorescent probes for the selective detection of chemical species inside mitochondria
Xu, Z., & Xu, L. (2016) · Chemical Communications · doi:10.1039/c5cc09248e · Cited by 291
Self-citation
Metadata
- Authors
- Xu, Z., Liu, X., Pan, J., & Spring, D. R.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 48
- Issue
- 39
- Pages
- 4764
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W1968777983
- Cited by
- 161
- References
- 2
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coumarin-derived transformable fluorescent sensor for Zn2+. https://app.cochat.ai/papers/10.1039/c2cc30963g
- The paper
- Xu, Z., Liu, X., Pan, J., & Spring, D. R. (2012). Coumarin-derived transformable fluorescent sensor for Zn2+. Chemical Communications. https://doi.org/10.1039/c2cc30963g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.