Microfluidic system for simultaneous optical measurement of platelet aggregation at multiple shear rates in whole blood
The DOI matches its Crossref record.
Abstract
Thrombosis is the pathological formation of platelet aggregates which occlude blood flow causing stroke and heart attack-the leading causes of death in developed nations. Instrumentation for diagnosing and exploring treatments for pathological platelet aggregation thus has the potential for major clinical impact. Most current thrombosis methods focus on single flow conditions, non-occlusive platelet adhesion, or low shear rates and so are limited in their application to comparative studies involving multiple, pathological test conditions (e.g., shear rate, stenotic geometries that mimic arteries, and rapid platelet accumulation to occlusion). The field could benefit from a low volume, high throughput, short analysis time, and low cost system while minimizing sample handling. We report on the design, fabrication, testing, and application of a microfluidic device and associated optical system for simultaneous measurement of platelet aggregation at multiple initial shear rates within four stenotic channels in label-free whole blood. Following computational design, requisite shear rates were achieved in the device by micro- surface milling a mold and subsequent PDMS casting. We applied the microfluidic system to measure platelet aggregation in whole porcine blood for shear rates spanning physiological to pathological flow conditions (500-13000 s(-1)). Real-time, non-contact, label-free, microscope-free measurements of platelet aggregation were acquired using an optical system comprising a 650 nm diode laser and a linear CCD. We observed fully occlusive platelet aggregation in less than 20 min above a threshold initial shear rate of 4000 s(-1), and no occlusive platelet aggregation below 1500 s(-1) (N = 86 trials). Accumulation of thrombus was consistent between laser intensity, light microscopy, histology, and mass flow rate measurements. The amount of blood volumes producing occlusion were dependent on shear rate. Times to occlusion were not found to be dependent on shear rate above the threshold level of 4000 s(-1). This microfluidic system enables measurement of the entire process of occlusive platelet thrombosis in whole, unlabeled blood, in vitro, at multiple shear rates. Such a system may be useful as a point-of-care diagnostic tool for studying anti-platelet therapies in individual blood samples from high-risk patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioprinted thrombosis-on-a-chip
Zhang, Y. S., Davoudi, F., Walch, P., Manbachi, A., Luo, X., Dell'Erba, V., Miri, A. K., Albadawi, H., Arneri, A., Li, X., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00380j · Cited by 227
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Monitoring in vitro thrombus formation with novel microfluidic devices
Westein, E., de Witt, S., Lamers, M., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2012.709653 · Cited by 54
Engineering the cardiac tissue microenvironment
Ronan, G., Bahcecioglu, G., Aliyev, N., & Zorlutuna, P. (2024) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0ea7 · Cited by 4
Metadata
- Authors
- Li, M., Ku, D. N., & Forest, C. R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 7
- Pages
- 1355
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2109139627
- Cited by
- 105
- References
- 0
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic system for simultaneous optical measurement of platelet aggregation at multiple shear rates in whole blood. https://app.cochat.ai/papers/10.1039/c2lc21145a
- The paper
- Li, M., Ku, D. N., & Forest, C. R. (2012). Microfluidic system for simultaneous optical measurement of platelet aggregation at multiple shear rates in whole blood. Lab on a Chip. https://doi.org/10.1039/c2lc21145a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.