The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Rapid screening of antibiotic toxicity in an automated microdroplet system
Abstract
We report an automated microfluidic platform for 'digitally' screening the composition space of droplets containing cocktails of small molecules and demonstrate the features of this system by studying epistatic interactions between antibiotics and Escherichia coli ATCC 25922. This system has several key characteristics: (i) it uses small (<100 μL) samples of liquids and suspensions of bacteria that are introduced directly into the chip; (ii) it generates a sequence of droplets with compositions, including reagents and bacterial cell suspensions that are programmed by the user; (iii) it exports the sequence of droplets to an external segment of tubing that is subsequently disconnected for incubation and storage; and (iv) after incubation of bacteria in droplets, the droplets are injected into a second device equipped with an in-line fiber optic spectrophotometer that measures cell growth. The system generates and fuses droplets with precise (<1% in standard deviation) control of liquid volumes and of the concentrations of input substrates. We demonstrate the application of this technology in determining the minimum inhibitory concentration and pair-wise interactions of ampicillin, tetracycline, and chloramphenicol against E. coli. The experiments consumed small volumes of reagents and required minutes to create the droplets and several hours for their incubation and analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of minimum inhibitory concentrations
Andrews, J. M. (2001) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/48.suppl_1.5 · Cited by 4,129
Multicomponent therapeutics for networked systems
Keith, C. T., Borisy, A. A., & Stockwell, B. R. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1609 · Cited by 769
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Drug interactions and the evolution of antibiotic resistance
Yeh, P. J., Hegreness, M. J., Aiden, A. P., & Kishony, R. (2009) · Nature Reviews Microbiology · doi:10.1038/nrmicro2133 · Cited by 350
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Self-citationDroplet microfluidics: A tool for biology, chemistry and nanotechnology
Mashaghi, S., Abbaspourrad, A., Weitz, D. A., & van Oijen, A. M. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.05.019 · Cited by 374
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
Self-citationConcentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Metadata
- Authors
- Churski, K., Kaminski, T. S., Jakiela, S., Kamysz, W., Baranska-Rybak, W., Weibel, D. B., & Garstecki, P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 9
- Pages
- 1629
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1992741965
- Cited by
- 228
- References
- 4
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.