Optical microplates for high-throughput screening of photosynthesis in lipid-producing algae
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
It is well known that biological systems respond to chemical signals as well as physical stimuli. The workhorses of high throughput screening, microplates and pipetting robots, are well suited for screening chemical stimuli; however, there are fewer options for screening physical stimuli, particularly those which involve temporal patterns. This paper presents an optical microplate for photonic high-throughput screening. The system provides addressable intensity and temporal control of LED light emission in each well, and operates on standard black-wall clear-bottom 96-well microplates, which prevent light spillover. Light intensity can be controlled to 7-bit resolution (128 levels), with a maximum intensity of 120 mE cm(-2). The temporal resolution, useful for studying dynamics of light-driven bioprocesses, can be as low as 10 μs. The microplate is used for high-throughput studies of light-dependent growth rates and photosynthetic efficiency in the model organism Dunaliella tertiolecta, a lipid-producing algae of interest in 2(nd) generation biofuels. By conducting 96 experiments in parallel, photoirradiance studies, which would require 2 years using conventional tools, can be completed in <2 weeks. In a 12 day culture, algal growth rates increase with total photon flux, as expected. Interestingly, the lipid production efficiency, defined as lipid production per unit photon flux per capita, increases nearly 5 fold at low light intensity (constant light) and at low duty cycle (pulsed light). High throughput protocols enabled by this system are conducive to systematic studies and discovery in the fields of photobiology and photochemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Systems Biology: Design Principles of Biological Circuits
Alon, U. (2006) · doi:10.1201/9781420011432 · Cited by 2,825
Nile red: a selective fluorescent stain for intracellular lipid droplets.
Greenspan, P., Mayer, E. P., & Fowler, S. D. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.3.965 · Cited by 2,543
Reverse engineering of biological complexity
Csete, M. E., & Doyle, J. C. (2002) · Science · doi:10.1126/science.1069981 · Cited by 1,215
Light requirements in microalgal photobioreactors: an overview of biophotonic aspects
Carvalho, A. P., Silva, S. O., Baptista, J. M., & Malcata, F. X. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-3047-8 · Cited by 521
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Cited by
Glemser, M., Heining, M., Schmidt, J., Becker, A., Garbe, D., Buchholz, R., & Brück, T. (2016) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-015-7144-6 · Cited by 135
Kim, H. S., Weiss, T. L., Thapa, H. R., Devarenne, T. P., & Han, A. (2014) · Lab on a Chip · doi:10.1039/c3lc51396c · Cited by 106
Heo, J., Cho, D.-H., Ramanan, R., Oh, H.-M., & Kim, H.-S. (2015) · Biochemical Engineering Journal · doi:10.1016/j.bej.2015.07.013 · Cited by 54
Morschett, H., Wiechert, W., & Oldiges, M. (2016) · Microbial Cell Factories · doi:10.1186/s12934-016-0433-7 · Cited by 36
Morschett, H., Schiprowski, D., Müller, C., Mertens, K., Felden, P., Meyer, J., Wiechert, W., & Oldiges, M. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26051 · Cited by 19
Metadata
- Authors
- Chen, M., Mertiri, T., Holland, T., & Basu, A. S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 20
- Pages
- 3870
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2140915572
- Cited by
- 50
- References
- 5
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.