CoChat

Automation of a Nile red staining assay enables high throughput quantification of microalgal lipid production

Open access
Morschett, Holger, Wiechert, Wolfgang, Oldiges, Marco · 2016 · Microbial Cell Factories

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index; 2 of the 26 sources its claims cite were checked for support.

Abstract

BACKGROUND: Within the context of microalgal lipid production for biofuels and bulk chemical applications, specialized higher throughput devices for small scale parallelized cultivation are expected to boost the time efficiency of phototrophic bioprocess development. However, the increasing number of possible experiments is directly coupled to the demand for lipid quantification protocols that enable reliably measuring large sets of samples within short time and that can deal with the reduced sample volume typically generated at screening scale. To meet these demands, a dye based assay was established using a liquid handling robot to provide reproducible high throughput quantification of lipids with minimized hands-on-time. RESULTS: Lipid production was monitored using the fluorescent dye Nile red with dimethyl sulfoxide as solvent facilitating dye permeation. The staining kinetics of cells at different concentrations and physiological states were investigated to successfully down-scale the assay to 96 well microtiter plates. Gravimetric calibration against a well-established extractive protocol enabled absolute quantification of intracellular lipids improving precision from ±8 to ±2 % on average. Implementation into an automated liquid handling platform allows for measuring up to 48 samples within 6.5 h, reducing hands-on-time to a third compared to manual operation. Moreover, it was shown that automation enhances accuracy and precision compared to manual preparation. It was revealed that established protocols relying on optical density or cell number for biomass adjustion prior to staining may suffer from errors due to significant changes of the cells' optical and physiological properties during cultivation. Alternatively, the biovolume was used as a measure for biomass concentration so that errors from morphological changes can be excluded. CONCLUSIONS: The newly established assay proved to be applicable for absolute quantification of algal lipids avoiding limitations of currently established protocols, namely biomass adjustment and limited throughput. Automation was shown to improve data reliability, as well as experimental throughput simultaneously minimizing the needed hands-on-time to a third. Thereby, the presented protocol meets the demands for the analysis of samples generated by the upcoming generation of devices for higher throughput phototrophic cultivation and thereby contributes to boosting the time efficiency for setting up algae lipid production processes.

Overview

CoChat Summary

TL;DR

The paper presents an automated Nile red staining assay in 96-well microtiter plates for absolute quantification of intracellular neutral lipids in *Chlorella vulgaris*, using biovolume instead of optical density or cell number for biomass standardization. Automation on a liquid handling robot measured up to 48 samples in 6.5 h, reduced hands-on time by 66%, and improved precision from ±8% to ±2% on average after gravimetric calibration.

Key findings

  • The optimized Nile red assay used 1 mg L−1 dye, 25% (v v−1) DMSO, 40 °C, excitation at 480 nm, and emission at 570–580 nm. Fluorescence was linear up to a biovolume of 0.2 µL mL−1; growing low-lipid cells stained quantitatively within 0.5 h, while starved high-lipid cells needed at least 2 h.
  • Gravimetric calibration showed linear correlation (R² = 0.991) between Nile red fluorescence and lipid content from 13.3–44.5% (w w−1). Average relative errors were ±2% for lipid fluorescence versus ±8% for gravimetry.
  • Optical density was unreliable for biomass adjustment: the OD750-to-biovolume ratio increased significantly (p < 0.05) by more than 60% across physiological states, from 1.08 ± 0.06 for exponentially growing cells to 1.81 ± 0.05 for N-starved cells with high lipid content, while average cell size shrank from approximately 6.5 µm to 3.4 µm.
  • Automation handled up to 48 samples per run in 6.5 h total runtime with 2.5 h hands-on time, versus 10.5 h total and 7.5 h hands-on manually, reducing runtime by 37% and hands-on time by 66%. Automated pipetting had 0.3% systematic error versus 0.6–1.0% manual, and technical replicate standard errors were 2.1% automated versus 4.3% manual.

Methods

  • *Chlorella vulgaris* 211–11b was cultivated axenically in enriched Bold’s Basal Medium under phototrophic shaking-flask conditions; different lipid contents were obtained by harvesting during growth or at different times during nitrogen starvation.
  • Biomass was measured by OD750 photometry and by a Coulter counter (MultiSizer 3, 30 µm capillary, volumetric control, 100 µL sample, 40 µA) to determine cell counts and biovolume, with particles sized 1.8–14 µm analyzed.
  • The Nile red assay was adapted from Chen et al. to 96-well MTP format and automated on a JANUS Integrator liquid handling platform with Varispan arm, MTP railgripper, Teleshake95 shaker/heater, and EnSpire photometer. Samples were diluted to a biovolume of 0.2 µL mL−1 before adding staining solution, yielding a final assay biovolume of 0.15 µL mL−1, and stained for 3 h. Gravimetric lipid quantification used a modified single-step chloroform–methanol extraction with lyophilized biomass, evaporation, and weighing. Pipetting accuracy and precision were determined gravimetrically with 10 replicates, and statistical comparisons used two-sided t-tests for unequal variances at 95% significance.

Limitations

  • The paper states that the contribution of each possible effect to the slowed staining kinetics of starved cells was not further investigated.
  • The paper states that reliable quantitative Nile red staining conditions are highly strain specific due to varying dye uptake, so individual gravimetric calibration is needed for cross-strain comparison; this study used only *C. vulgaris* as the model organism.
  • Evident from the text: the Nile red assay specifically detects neutral lipids, whereas gravimetric extraction measures total cellular lipids. This explains the offset where growing cells showed 13.3% (w w−1) lipid content by gravimetry but no detectable Nile red signal.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s12934-016-0433-7

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Biovolume-specific optical density and average cell size of C. vulgaris at different physiological states. Depending on the physiological state observed, the cells significantly differ in their optical properties and cell size. Thereby, biomass determination across different states by either optical signals or cell number is distorted. Cell samples originated from phototrophic shaking flask cultivations. Error bars deviated from samples (biological replicates) of the respective fermentation phases (n ≥ 3)
Fig. 1 Biovolume-specific optical density and average cell size of C. vulgaris at different physiological states. Depending on the physiological state observed, the cells significantly differ in their optical properties and cell size. Thereby, biomass determination across different states by either optical signals or cell number is distorted. Cell samples originated from phototrophic shaking flask cultivations. Error bars deviated from samples (biological replicates) of the respective fermentation phases (n ≥ 3)CC BY · PubMed Central
Fig. 2 Typical fluorescence spectra of the lipid assay. Staining of cells with the lipid probe Nile red and subsequent excitation at 480 nm results in a specific, lipid correlated fluorescence with a maximum at 570–580 nm. Biomass with a biovolume of 0.15 µL mL−1 was stained for 3 h at 40 °C in 25 % (v v−1) DMSO with 1 mg L−1 Nile red, excitation at 480 nm
Fig. 2 Typical fluorescence spectra of the lipid assay. Staining of cells with the lipid probe Nile red and subsequent excitation at 480 nm results in a specific, lipid correlated fluorescence with a maximum at 570–580 nm. Biomass with a biovolume of 0.15 µL mL−1 was stained for 3 h at 40 °C in 25 % (v v−1) DMSO with 1 mg L−1 Nile red, excitation at 480 nmCC BY · PubMed Central
Fig. 3 Characterization of the Nile red staining. a Biomass specific lipid fluorescence. After an initial linear correlation, the fluorescence signal saturates above a biovolume of 0.2 µL mL−1 for both cell types (dashed line). b Time-dependent staining kinetics of cells with a biovolume of 0.15 µL mL−1. In contrast to staining growing cells containing low levels of lipids (0.5 h), non-growing cells with high lipid content need significantly more time (2 h) for quantitative staining. Cells were stained in 25 % (v v−1) DMSO containing 1 mg L−1 Nile red at 40 °C, excitation at 480 nm. Error bars deviated from analytical replicates (n = 5)
Fig. 3 Characterization of the Nile red staining. a Biomass specific lipid fluorescence. After an initial linear correlation, the fluorescence signal saturates above a biovolume of 0.2 µL mL−1 for both cell types (dashed line). b Time-dependent staining kinetics of cells with a biovolume of 0.15 µL mL−1. In contrast to staining growing cells containing low levels of lipids (0.5 h), non-growing cells with high lipid content need significantly more time (2 h) for quantitative staining. Cells were stained in 25 % (v v−1) DMSO containing 1 mg L−1 Nile red at 40 °C, excitation at 480 nm. Error bars deviated from analytical replicates (n = 5)CC BY · PubMed Central
Fig. 4 Gravimetric calibration of the lipid assay. The Nile red staining deviated biomass specific lipid fluorescence is linearly correlated with the fraction of intracellular lipids measured by extraction and subsequent gravimetric analysis. Cells with a biovolume of 0.15 µL mL−1 were stained for 3 h at 40 °C in 25 % (v v−1) DMSO with 1 mg L−1 Nile red. Error bars of the Nile red assay deviated from analytical replicates (n = 5). Error bars of the gravimetric measurement from technical replicates (n = 3)
Fig. 4 Gravimetric calibration of the lipid assay. The Nile red staining deviated biomass specific lipid fluorescence is linearly correlated with the fraction of intracellular lipids measured by extraction and subsequent gravimetric analysis. Cells with a biovolume of 0.15 µL mL−1 were stained for 3 h at 40 °C in 25 % (v v−1) DMSO with 1 mg L−1 Nile red. Error bars of the Nile red assay deviated from analytical replicates (n = 5). Error bars of the gravimetric measurement from technical replicates (n = 3)CC BY · PubMed Central
Fig. 5 Assay automation significantly enhances analytical throughput. Using the described liquid handling platform, hands-on-time and total runtime can be reduced by 66 and 37 %, respectively. Arrows represent the duration of individual assay steps, while the respective coloured fractions represent hands-on-times. Blue pre-dilution of samples, red measurement and adjustion of biovolume, yellow staining, green sample transfer and fluorescence measurement
Fig. 5 Assay automation significantly enhances analytical throughput. Using the described liquid handling platform, hands-on-time and total runtime can be reduced by 66 and 37 %, respectively. Arrows represent the duration of individual assay steps, while the respective coloured fractions represent hands-on-times. Blue pre-dilution of samples, red measurement and adjustion of biovolume, yellow staining, green sample transfer and fluorescence measurementCC BY · PubMed Central
Fig. 6 Compared to preparation by hand, automated liquid handling increases accuracy and precision. a Although liquid handling robots suffer from systematic and stochastic errors as well, these are typically constant, while manual pipetting by different operators (four persons in this case) can result in significant differences. b Daily operator performance can induce significant fluctuations of manual pipetting performance. Automated pipetting conducted by JANUS Integrator liquid handling platform and manual pipetting by four different operators using an Eppendorf Research Plus pipette. Volumes determined gravimetrically using a semi-micro balance and normalized to the respective target volumes. Error bars deviated from analytical replicates (n = 10)
Fig. 6 Compared to preparation by hand, automated liquid handling increases accuracy and precision. a Although liquid handling robots suffer from systematic and stochastic errors as well, these are typically constant, while manual pipetting by different operators (four persons in this case) can result in significant differences. b Daily operator performance can induce significant fluctuations of manual pipetting performance. Automated pipetting conducted by JANUS Integrator liquid handling platform and manual pipetting by four different operators using an Eppendorf Research Plus pipette. Volumes determined gravimetrically using a semi-micro balance and normalized to the respective target volumes. Error bars deviated from analytical replicates (n = 10)CC BY · PubMed Central
Fig. 7 Schematic representation of the workflow for automated quantification of intracellular neutral lipids at high throughput. The protocol was designed to run on a JANUS Integrator liquid handling platform ensuring minimized hands-on-time
Fig. 7 Schematic representation of the workflow for automated quantification of intracellular neutral lipids at high throughput. The protocol was designed to run on a JANUS Integrator liquid handling platform ensuring minimized hands-on-timeCC BY · PubMed Central

Verification

Claims the paper makes

2 Valid · 0 Not valid · 13 Not checked · 44 Own results and interpretations

22 more claims

Create a free account to see all 59 claims and to verify the 24 references still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 50 references

Research works printed but not linked: 1

  1. Beijerinck MW. Culturversuche mit Zoochlorellen und anderen niederen Algen. Btg Ztg. 1890;45:725–40.

Cited by

See all 36

Metadata

Authors
Morschett, H., Wiechert, W., & Oldiges, M.
Affiliations
Forschungszentrum Jülich (DE)
Corresponding author
Oldiges, Marco
Venue
Microbial Cell Factories
Published
2016-02-09
Volume
15
Issue
1
Pages
34-34
ISSN
1475-2859 (ISSN-L)
OpenAlex
W2257190949
Cited by
36
References
50
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 6 · 2021: 3 · 2020: 9 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 3
FWCI
1.09
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Microbial Cell Factories (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Bundesministerium für Wirtschaft und Energie (DE) (KF2519304CS3)
Topics
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Algal biology and biofuel production
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Microbial Metabolic Engineering and Bioproduction
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Lipid metabolism and biosynthesis
Keywords
microalgal lipid production, Nile Red staining, automated liquid handling, dimethyl sulfoxide, 96-well plate, gravimetric calibration, phototrophic cultivation, algal biofuels
MeSH terms
Automation, Calibration, Chlorella, Lipids, Oxazines, Reference Standards, Spectrometry, Fluorescence, Staining and Labeling, Reproducibility of Results, Biomass, Cell Size, High-Throughput Screening Assays, Microalgae

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automation of a Nile red staining assay enables high throughput quantification of microalgal lipid production. https://app.cochat.ai/papers/10.1186/s12934-016-0433-7
The paper
Morschett, H., Wiechert, W., & Oldiges, M. (2016). Automation of a Nile red staining assay enables high throughput quantification of microalgal lipid production. Microbial Cell Factories. https://doi.org/10.1186/s12934-016-0433-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.