Acoustofluidics 20: Applications in acoustic trapping
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This part of the Acoustofluidics tutorial series reviews applications in acoustic trapping of micron-sized particles and cells in microfluidic systems. Acoustic trapping enables non-invasive and non-contact immobilisation of cells and particles in microfluidic systems. Acoustic trapping has been used for reducing the time needed to create 3D cell clusters, enhance particle-based bioassays and facilitated interaction studies of both cells and particles. An area that is increasingly interesting is the use of acoustic trapping for enriching low concentration samples and the washing or fractioning of cell populations prior to sensitive detection methods (MALDI-MS, PCR etc.) The main focus of the review is systems where particles can be retained against a flow while applications in which particles are positioned in a stationary fluid will be addressed in part 21 of the Acoustofluidics tutorial series (M. Wiklund, S. Radel and J. J. Hawkes, Lab Chip, 2012, 12, ).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
Acoustofluidics 7: The acoustic radiation force on small particles
Bruus, H. (2012) · Lab on a Chip · doi:10.1039/c2lc21068a · Cited by 1,019
Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW)
Shi, J., Ahmed, D., Mao, X., Lin, S.-C. S., Lawit, A., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b910595f · Cited by 723
Review of cell and particle trapping in microfluidic systems
Nilsson, J., Evander, M., Hammarström, B., & Laurell, T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.017 · Cited by 534
Self-citationAcoustofluidics 14: Applications of acoustic streaming in microfluidic devices
Wiklund, M., Green, R., & Ohlin, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40203c · Cited by 521
Acoustofluidics 8: Applications of acoustophoresis in continuous flow microsystems
Lenshof, A., Magnusson, C., & Laurell, T. (2012) · Lab on a Chip · doi:10.1039/c2lc21256k · Cited by 353
Whole Cell Patch Clamp Recording Performed on a Planar Glass Chip
Fertig, N., Blick, R. H., & Behrends, J. C. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75646-4 · Cited by 347
Acoustofluidics 12: Biocompatibility and cell viability in microfluidic acoustic resonators
Wiklund, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40201g · Cited by 338
Noninvasive Acoustic Cell Trapping in a Microfluidic Perfusion System for Online Bioassays
Evander, M., Johansson, L., Lilliehorn, T., Piskur, J., Lindvall, M., Johansson, S., Almqvist, M., Laurell, T., & Nilsson, J. (2007) · Analytical Chemistry · doi:10.1021/ac061576v · Cited by 281
Self-citationAcoustofluidics 5: Building microfluidic acoustic resonators
Lenshof, A., Evander, M., Laurell, T., & Nilsson, J. (2012) · Lab on a Chip · doi:10.1039/c1lc20996e · Cited by 252
Self-citationLee, J., Teh, S.-Y., Lee, A., Kim, H. H., Lee, C., & Shung, K. K. (2009) · Applied Physics Letters · doi:10.1063/1.3206910 · Cited by 244
Hultström, J., Manneberg, O., Dopf, K., Hertz, H. M., Brismar, H., & Wiklund, M. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.07.024 · Cited by 220
Acoustic Cell Filter for High Density Perfusion Culture of Hybridoma Cells
TRAMPLER, F., Sonderhoff, S. A., Pui, P. W. S., Kilburn, D. G., & Piret, J. M. (1994) · Nature Biotechnology · doi:10.1038/nbt0394-281 · Cited by 147
Ultrasound-controlled cell aggregation in a multi-well chip
Vanherberghen, B., Manneberg, O., Christakou, A. E., Frisk, T. W., Ohlin, M., Hertz, H. M., Önfelt, B., & Wiklund, M. (2010) · Lab on a Chip · doi:10.1039/c004707d · Cited by 137
Open-access microfluidic patch-clamp array with raised lateral cell trapping sites
Lau, A. Y., Hung, P. J., Wu, A. R., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b608439g · Cited by 99
Bazou, D., Coakley, W. T., Hayes, A. J., & Jackson, S. K. (2008) · Toxicology in Vitro · doi:10.1016/j.tiv.2008.03.014 · Cited by 96
Positioning, displacement, and localization of cells using ultrasonic forces
Haake, A., Neild, A., Radziwill, G., & Dual, J. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20540 · Cited by 96
Bazou, D., Kuznetsova, L. A., & Coakley, W. T. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.12.007 · Cited by 95
Pui, P. W. S., TRAMPLER, F., Sonderhoff, S. A., Gröschl, M., Kilburn, D. G., & Piret, J. M. (1995) · Biotechnology Progress · doi:10.1021/bp00032a005 · Cited by 85
Liu, J., Kuznetsova, L. A., Edwards, G. O., Xu, J., Ma, M., Purcell, W. M., Jackson, S. K., & Coakley, W. T. (2007) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21345 · Cited by 83
Dynamic arraying of microbeads for bioassays in microfluidic channels
Lilliehorn, T., Evander, M., Simu, U., Johansson, S. A. I., Almqvist, M., Nilsson, J., & Laurell, T. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.07.003 · Cited by 76
Self-citationSpengler, J. F., Jekel, M., Christensen, K. T., et al. (2000) · Bioseparation · doi:10.1023/a:1011113826753 · Cited by 70
Bazou, D., Kearney, R., Mansergh, F. C., Bourdon, C., Farrar, J., & Wride, M. A. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.10.019 · Cited by 56
Cell–cell contact and membrane spreading in an ultrasound trap
Coakley, W. T., Bazou, D., Morgan, J., Foster, G. A., Archer, C. W., Powell, K. A., Borthwick, K. A. J., Twomey, C., & Bishop, J. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2004.01.002 · Cited by 52
Acoustofluidics 21: ultrasound-enhanced immunoassays and particle sensors
Wiklund, M., Radel, S., & Hawkes, J. J. (2012) · Lab on a Chip · doi:10.1039/c2lc41073g · Cited by 46
Bazou, D., Coakley, W. T., Meek, K. M., Yang, M. Y., & Pham, D. T. (2004) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2004.04.075 · Cited by 22
Bazou, D., Blain, E. J., & Coakley, W. T. (2008) · Molecular Membrane Biology · doi:10.1080/09687680701618365 · Cited by 13
Cited by
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping
Augustsson, P., Karlsen, J. T., Su, H.-W., Bruus, H., & Voldman, J. (2016) · Nature Communications · doi:10.1038/ncomms11556 · Cited by 246
Independent trapping and manipulation of microparticles using dexterous acoustic tweezers
Courtney, C. R. P., Demore, C. E. M., Wu, H., Grinenko, A., Wilcox, P. D., Cochran, S., & Drinkwater, B. W. (2014) · Applied Physics Letters · doi:10.1063/1.4870489 · Cited by 218
Microfluidic droplet handling by bulk acoustic wave (BAW) acoustophoresis
Leibacher, I., Reichert, P., & Dual, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00083a · Cited by 192
Biomolecular Ultrasound and Sonogenetics
Maresca, D., Lakshmanan, A., Abedi, M., Bar-Zion, A., Farhadi, Lu, G. J., Szablowski, J. O., Wu, D., Yoo, S., & Shapiro, M. G. (2018) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-060817-084034 · Cited by 190
Metadata
- Authors
- Evander, M., & Nilsson, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 22
- Pages
- 4667
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2128065776
- Cited by
- 201
- References
- 27
- FWCI
- 9.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.