Free-standing nickel oxide nanoflake arrays: synthesis and application for highly sensitive non-enzymatic glucose sensors
Abstract
We report a seed-mediated hydrothermal growth of free-standing nickel hydroxide [Ni(OH)(2)] and nickel oxide (NiO) nanoflake arrays and their implementation as electrodes for non-enzymatic glucose sensors. Ni(OH)(2) nanoflakes were converted into porous NiO nanoflakes upon thermal annealing in air at temperatures of 300 °C or above. NiO nanoflake-arrayed sensors achieve an excellent glucose sensitivity of ∼8500 μA cm(-2) mM(-1) and a low detection limit of 1.2 μM glucose at an applied bias of 0.5 V vs. Ag/AgCl. The fabrication of the nanoflake electrode avoids the use of polymer binders representing additional advantage over the conventional powder based glucose sensors. Furthermore, they show good specificity to glucose in the presence of ascorbic acid, d-lactose and d-fructose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Ni(OH) 2 Nanoplates Grown on Graphene as Advanced Electrochemical Pseudocapacitor Materials
Wang, H., Casalongue, H. S., Liang, Y., & Dai, H. (2010) · Journal of the American Chemical Society · doi:10.1021/ja102267j · Cited by 2,042
Self-citation
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Nickel oxide nanoparticles: Synthesis and spectral studies of interactions with glucose
El-Kemary, M., Nagy, N., & El-Mehasseb, I. (2013) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2013.05.018 · Cited by 658
Advances in non-enzymatic glucose sensors based on metal oxides
Zhu, H., Li, L., Zhou, W., Shao, Z., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02037b · Cited by 473
Wang, G., Ling, Y., & Li, Y. (2012) · Nanoscale · doi:10.1039/c2nr32222f · Cited by 377
Self-citationNanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Metadata
- Authors
- Wang, G., Lu, X., Zhai, T., Ling, Y., Wang, H., Tong, Y., & Li, Y.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 4
- Issue
- 10
- Pages
- 3123
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2091745520
- Cited by
- 248
- References
- 2
- FWCI
- 17.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Free-standing nickel oxide nanoflake arrays: synthesis and application for highly sensitive non-enzymatic glucose sensors. https://app.cochat.ai/papers/10.1039/c2nr30302g
- The paper
- Wang, G., Lu, X., Zhai, T., Ling, Y., Wang, H., Tong, Y., & Li, Y. (2012). Free-standing nickel oxide nanoflake arrays: synthesis and application for highly sensitive non-enzymatic glucose sensors. Nanoscale. https://doi.org/10.1039/c2nr30302g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.