The DOI matches its Crossref record.
Photon upconverting nanoparticles for luminescent sensing of temperature
Open accessAbstract
Photon upconverting nanoparticles convert near-infrared into visible light (anti-Stokes emission), which strongly reduces the background of autofluorescence and light scattering in biological materials. Hexagonal NaYF(4) nanocrystals doped with Yb(3+) as the sensitizer and Er(3+)/Ho(3+)/Tm(3+) as the activator display at least two emission lines that respond differently to temperature changes. The ratio of the main emission line intensities enables a self-referenced optical readout of the temperature in the physiologically relevant range from 20 to 45 °C. Upconverting nanoparticles of the type NaYF(4):Yb, Er covered by an inactive shell of NaYF(4) are bright and allow for resolving temperature differences of less than 0.5 °C in the physiological range. The optical readout of this nanoparticle-based thermometer offers many options for imaging the two-dimensional distribution of temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Upconversion Nanoparticles: Design, Nanochemistry, and Applications in Theranostics
Chen, G., Qiu, H., Prasad, P. N., & Chen, X. (2014) · Chemical Reviews · doi:10.1021/cr400425h · Cited by 2,699
Luminescent probes and sensors for temperature
Wang, X.-D., Wolfbeis, O. S., & Meier, R. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60102a · Cited by 1,647
Self-citationAn overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Self-citationLanthanide‐Based Thermometers: At the Cutting‐Edge of Luminescence Thermometry
Brites, C. D. S., Balabhadra, S., & Carlos, L. D. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801239 · Cited by 1,173
Lanthanide Nanoparticles: From Design toward Bioimaging and Therapy
Dong, H., Du, S.-R., Zheng, X.-Y., Lyu, G.-M., Sun, L.-D., Li, L.-D., Zhang, P.-Z., Zhang, C., & Yan, C.-H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00091 · Cited by 1,126
Zhu, X., Feng, W., Chang, J., Tan, Y.-W., Li, J., Chen, M., Sun, Y., & Li, F. (2016) · Nature Communications · doi:10.1038/ncomms10437 · Cited by 1,013
Lanthanides in Luminescent Thermometry
Brites, C. D. S., Millán, A., & Carlos, L. D. (2016) · Handbook on the Physics and Chemistry of Rare Earths · doi:10.1016/bs.hpcre.2016.03.005 · Cited by 536
Anti-Stokes shift luminescent materials for bio-applications
Zhu, X., Su, Q., Feng, W., & Li, F. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00415f · Cited by 496
Gorris, H. H., & Wolfbeis, O. S. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201208196 · Cited by 436
Self-citationZhu, X., Li, J., Qiu, X., Liu, Y., Feng, W., & Li, F. (2018) · Nature Communications · doi:10.1038/s41467-018-04571-4 · Cited by 276
Metadata
- Authors
- Sedlmeier, A., Achatz, D. E., Fischer, L. H., Gorris, H. H., & Wolfbeis, O. S.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 4
- Issue
- 22
- Pages
- 7090
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2162138395
- Cited by
- 235
- References
- 0
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.