Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrophoretic deposition under modulated electric fields: a review

Ammam, Malika · 2012 · RSC Advances

Abstract

Classical electrophoretic deposition (EPD) relies on continuous direct current (CDC) to deposit charged particles on electrodes. In recent decades, modulated electric fields such as pulsed direct current (PDC) and alternating current (AC) have been investigated. This paper reviews EPD under these modulated electric fields and major applications of the deposited microstructures. The paper starts with a short overview of EPD principals such as the electrical double layer of the charged particle, electrophoretic mobility and main suspension parameters including zeta potential, particle size, conductivity, viscosity and stability of the suspension. The EPD mechanisms from the earliest model reported by Hamaker and Verwey to latest models including Sarkar and Nicholson model and influence of the electrohydrodynamics and electroosmosis as well as electrode surface and its electrochemical double layer on the deposition process have been briefly discussed. Two categories of modulated electric fields, PDC and AC fields have been addressed with their advantages and disadvantages. It is found that compared to CDC, PDC offers the advantage of: i) reducing the coalescence between gas bubbles induced by water electrolysis from aqueous suspensions, hence yielding deposition of smooth and uniform coatings, ii) reducing aggregation and disaggregation of nanometer sized particles, leading to formation of uniform and homogenous deposits and, iii) PDC generates low change in pH near the electrode, thus it is convenient for deposition of biochemical and biological species in their highly active states. The main disadvantage of PDC over CDC lies in the decrease of the deposition yield. The latter can be more pronounced if low time-pulses are used. Various categories of AC signals including symmetrical fields with no net DC component and asymmetrical AC signals without and with net DC component have been discussed. Overall, the deposition rate under AC fields increases with polarization time and amplitude. With respect to frequency, the deposition rate increases with frequency up to certain value then drops at elevated frequencies. It is noted that deposition under AC signals offers the possibility to produce superior quality coatings from aqueous suspensions because electrolysis of water as well as particle orientation during the deposition could be controlled. From the application standpoint, PDC and AC, offers new application perspectives such as in biotechnology. Because under modulated electric fields, EPD can now be accomplished from aqueous suspensions with low water electrolysis rates, a variety of biochemical and biological species can be deposited to yield highly active layers suitable for a wide range of applications including biosensors, biofuel cells and bioreactors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c2ra01342h

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Ammam, M.
Venue
RSC Advances
Published
2012
Volume
2
Issue
20
Pages
7633
ISSN
2046-2069 (ISSN-L)
OpenAlex
W1996423230
Cited by
210
References
1
FWCI
9.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrophoretic deposition under modulated electric fields: a review. https://app.cochat.ai/papers/10.1039/c2ra01342h
The paper
Ammam, M. (2012). Electrophoretic deposition under modulated electric fields: a review. RSC Advances. https://doi.org/10.1039/c2ra01342h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.