A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Gold surfaces intended for surface plasmon resonance sensors have been derivatized with a flexible matrix composed of carboxymethylated dextran to provide fast and efficient coupling of proteins and other ligands at low concentrations using the principles of ionic pre-concentration; these hydrophilic and protein compatible hydrogel surfaces allow increased immobilization capacity as compared to monolayer based coatings, for applications in biospecific interaction analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of monolayer films by the spontaneous assembly of organic thiols from solution onto gold
Bain, C. D., Troughton, E. B., Tao, Y. T., Evall, J., Whitesides, G. M., & Nuzzo, R. G. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00183a049 · Cited by 3,393
Porter, M. D., Bright, T. B., Allara, D. L., & Chidsey, C. E. D. (1987) · Journal of the American Chemical Society · doi:10.1021/ja00246a011 · Cited by 3,163
Surface plasmon resonance for gas detection and biosensing
Liedberg, B., Nylander, C., & Lunström, I. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85036-7 · Cited by 2,539
Adsorption of bifunctional organic disulfides on gold surfaces
Nuzzo, R. G., & Allara, D. L. (1983) · Journal of the American Chemical Society · doi:10.1021/ja00351a063 · Cited by 2,316
Bain, C. D., Evall, J., & Whitesides, G. M. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00200a039 · Cited by 922
Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Cullen, D. C., Brown, R. G. W., & Lowe, C. R. (1987) · Biosensors · doi:10.1016/0265-928x(87)85002-2 · Cited by 224
Size and charge distribution of macromolecules in living systems
Gianazza, E., & Righetti, P. G. (1980) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)81438-7 · Cited by 91
Immunoassay based on surface plasmon oscillations
Mayo, C. S., & Hallock, R. B. (1989) · Journal of Immunological Methods · doi:10.1016/0022-1759(89)90295-0 · Cited by 62
Cited by
Formation and Structure of Self-Assembled Monolayers
Ulman, A. (1996) · Chemical Reviews · doi:10.1021/cr9502357 · Cited by 7,906
Johnsson, B., Löfås, S., & Lindquist, G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90424-r · Cited by 1,262
Self-citationHow Strong Is a Covalent Bond?
Grandbois, M., Beyer, M., Rief, M., Clausen-Schaumann, H., & Gaub, H. E. (1999) · Science · doi:10.1126/science.283.5408.1727 · Cited by 1,095
Karlsson, R., Michaelsson, A., & Mattsson, L. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90331-9 · Cited by 1,077
Stenberg, E., Persson, B., Roos, H., & Urbaniczky, C. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90284-f · Cited by 1,059
Optical biosensors in drug discovery
Cooper, M. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd838 · Cited by 1,015
Biosensing with surface plasmon resonance — how it all started
Liedberg, B., Nylander, C., & Lundström, I. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96965-2 · Cited by 684
Holcomb, I. N., Kabakoff, R. C., Chan, B., Baker, T. W., Gurney, A., Henzel, W., Nelson, C., Lowman, H. B., Wright, B. D., Skelton, N. J., et al. (2000) · The EMBO Journal · doi:10.1093/emboj/19.15.4046 · Cited by 661
Schuck, P. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.541 · Cited by 657
Lahiri, J., Isaacs, L., Tien, J., & Whitesides, G. M. (1999) · Analytical Chemistry · doi:10.1021/ac980959t · Cited by 601
Karlsson, R., & Fält, A. (1997) · Journal of Immunological Methods · doi:10.1016/s0022-1759(96)00195-0 · Cited by 568
Design of Folic Acid‐Conjugated Nanoparticles for Drug Targeting
Stella, B., Arpicco, S., Peracchia, M. T., Desmaële, D., Hoebeke, J., Renoir, M., D'Angelo, J., Cattel, L., & Couvreur, P. (2000) · Journal of Pharmaceutical Sciences · doi:10.1002/1520-6017(200011)89:11<1452::aid-jps8>3.0.co;2-p · Cited by 553
Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
Myszka, D. G. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80157-7 · Cited by 552
Biospecific interaction analysis using biosensor technology
Malmqvist, M. (1993) · Nature · doi:10.1038/361186a0 · Cited by 532
Principles of biosensing with an extended coupling matrix and surface plasmon resonance
Liedberg, B., Lundström, I., & Stenberg, E. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)85239-7 · Cited by 524
van der Linden, R. H. J., Frenken, L. G. J., de Geus, B., Harmsen, M. M., Ruuls, R. C., Stok, W., de Ron, L., Wilson, S., Davis, P., & Verrips, C. T. (1999) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/s0167-4838(99)00030-8 · Cited by 471
SPR for molecular interaction analysis: a review of emerging application areas
Karlsson, R. (2004) · Journal of Molecular Recognition · doi:10.1002/jmr.660 · Cited by 449
Fägerstam, L. G., Frostell-Karlsson, Å., Karlsson, R., Persson, B., & Rönnberg, I. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80137-j · Cited by 437
Supported membranes on soft polymer cushions: fabrication, characterization and applications
Sackmann, E., & Tanaka, M. (2000) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01412-2 · Cited by 417
Wijaya, E., Lenaerts, C., Maricot, S., Hastanin, J., Habraken, S., Vilcot, J.-P., Boukherroub, R., & Szunerits, S. (2011) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2011.05.001 · Cited by 377
Towards on-site pathogen detection using antibody-based sensors
Skottrup, P. D., Nicolaisen, M., & Justesen, A. F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.045 · Cited by 352
Hydrogels and Their Role in Biosensing Applications
Herrmann, A., Haag, R., & Schedler, U. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100062 · Cited by 332
Heideman, R. G., & Lambeck, P. V. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00283-x · Cited by 331
Surface Plasmon Resonance-Based Immunoassays
Mullett, W. M., Lai, E. P. C., & Yeung, J. M. (2000) · Methods · doi:10.1006/meth.2000.1039 · Cited by 322
Chen, W., Yi, P., Zhang, Y., Zhang, L., Deng, Z., & Zhang, Z. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am2009647 · Cited by 291
Huang, W., Kim, J.-B., Bruening, M. L., & Baker, G. L. (2002) · Macromolecules · doi:10.1021/ma011159e · Cited by 276
Integrated fluid handling system for biomolecular interaction analysis
Sjoelander, S., & Urbaniczky, C. (1991) · Analytical Chemistry · doi:10.1021/ac00020a025 · Cited by 270
Molecular recognition in the HIV-1 capsid/cyclophilin A complex 1 1Edited by J. A. Wells
Yoo, S., Myszka, D. G., Yeh, C.-Y., McMurray, M., Hill, C. P., & Sundquist, W. I. (1997) · Journal of Molecular Biology · doi:10.1006/jmbi.1997.1051 · Cited by 264
Collings, A. F., & Caruso, F. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/11/005 · Cited by 258
Chemical sensors for portable, handheld field instruments
Wilson, D. M., Hoyt, S., Janata, J., Booksh, K., & Obando, L. (2001) · IEEE Sensors Journal · doi:10.1109/7361.983465 · Cited by 258
Salamon, Z., Macleod, H. A., & Tollin, G. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78308-5 · Cited by 254
Nanogold-plasmon-resonance-based glucose sensing
Aslan, K., Lakowicz, J. R., & Geddes, C. D. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.03.032 · Cited by 244
Surface plasmon resonance and its use in biomolecular interaction analysis (BIA)
Szabo, A., Stolz, L., & Granzow, R. (1995) · Current Opinion in Structural Biology · doi:10.1016/0959-440x(95)80064-6 · Cited by 238
Mechanisms of tumor necrosis factor-α (TNF-α) hyperalgesia
Watkins, L. R., Goehler, L. E., Relton, J., Brewer, M. T., & Maier, S. F. (1995) · Brain Research · doi:10.1016/0006-8993(95)00715-3 · Cited by 225
Arthritogenic Monoclonal Antibodies from K/BxN Mice
Maccioni, M., Zeder-Lutz, G., Huang, H., Ebel, C., Gerber, P., Hergueux, J., Marchal, P., Duchatelle, V., Degott, C., van Regenmortel, M., et al. (2002) · The Journal of Experimental Medicine · doi:10.1084/jem.20011941 · Cited by 220
“bit anti–mouse Fc or anti-GPI mAbs immobilized on the sensor chip via amino groups (12).”
MethodA commercial solution for surface plasmon sensing
Melendez, J., Carr, R., Bartholomew, D. U., Kukanskis, K., Elkind, J., Yee, S., Furlong, C., & Woodbury, R. (1996) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(97)80057-3 · Cited by 206
Analysis of macromolecular interactions using immobilized ligands
Chaiken, I., Rosé, S., & Karlsson, R. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90329-6 · Cited by 182
Binary and ternary complexes between T-cell receptor, class II MHC and superantigen in vitro
Seth, A., Stern, L. J., Ottenhoff, T. H. M., Engel, I., Owen, M. J., Lamb, J. R., Klausner, R. D., & Wiley, D. C. (1994) · Nature · doi:10.1038/369324a0 · Cited by 180
Effect of polysaccharide structure on protein adsorption
McArthur, S. L., McLean, K. M., Kingshott, P., St John, H. A. W., Chatelier, R. C., & Griesser, H. J. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00086-7 · Cited by 180
Godet, M., Grosclaude, J., Delmas, B., & Laude, H. (1994) · Journal of Virology · doi:10.1128/jvi.68.12.8008-8016.1994 · Cited by 179
“mouse (RAM) IgG Fc immunoglobulins (RAMFc; Pharmacia) were first covalently linked to dextran chips (27).”
MethodBiochemical aspects of biosensors
Byfield, M. P., & Abuknesha, R. A. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)80038-3 · Cited by 173
Schmitt, L., Ludwig, M., Gaub, H. E., & Tampé, R. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76863-9 · Cited by 171
“Here not more than 40% of the potential binding sites on the polymer can be derivatized with the ligand (Lo¨fás and Johnson, 1990; Lo¨fás, 1995).”
BackgroundMethodElender, G., Kühner, M., & Sackmann, E. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)83292-1 · Cited by 160
Glycation of monoclonal antibodies impairs their ability to bind antigen
KENNEDY, D. M., SKILLBN, A. W., & SELF, C. H. (2008) · Clinical and Experimental Immunology · doi:10.1111/j.1365-2249.1994.tb06133.x · Cited by 74
Metadata
- Authors
- Löfås, S., & Johnsson, B.
- Venue
- J. Chem. Soc., Chem. Commun.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1990
- Issue
- 21
- Pages
- 1526-1528
- ISSN
- 0022-4936 (ISSN-L)
- OpenAlex
- W2164929179
- Cited by
- 766
- References
- 9
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.