The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensitive and selective electrochemical detection of chromium(vi) based on gold nanoparticle-decorated titania nanotube arrays
Abstract
Owing to the severe toxicity and mobility of Cr(VI) in biological and environmental systems, it is of great importance to develop convenient and reliable methods for its detection. Here we report on a facile and effective electrochemical technique for monitoring Cr(VI) concentrations based on the utilization of Au nanoparticle-decorated titania nanotubes (TiO2NTs) grown on a titanium substrate. It was found that the electrochemical reduction of Cr(VI) at the Ti/TiO2NT/Au electrode exhibited an almost 23 fold improvement in activity as compared to a polycrystalline gold electrode, due to its nanoparticle/nanotubular heterojunction infrastructure. As a result, the Ti/TiO2NT/Au electrode demonstrated a wide linear concentration range from 0.10 μM to 105 μM, a low detection limit of 0.03 μM, and a high sensitivity of 6.91 μA μM(-1) Cr(VI) via amperometry, satisfying the detection requirements of the World Health Organization (WHO). Moreover, the Ti/TiO2NT/Au electrode exhibited good resistance against interference from coexisting Cr(III) and other metal ions, and excellent recovery for Cr(VI) detection in both tap and lake water samples. These attributes suggest that this hybrid sensor has strong potential in applications for the selective detection of Cr(VI).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetics of chromium(III) oxidation to chromium(VI) by reaction with manganese dioxide
Eary, L. E., & Rai, D. (1987) · Environmental Science & Technology · doi:10.1021/es00165a005 · Cited by 496
Cited by
A review on detection of heavy metal ions in water—An electrochemical approach
Gumpu, M. B., Sethuraman, S., Krishnan, U. M., & Rayappan, J. B. B. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.02.122 · Cited by 1,027
Maduraiveeran, G., Sasidharan, M., & Jin, W. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100574 · Cited by 321
Self-citationElectrochemical processes for the environmental remediation of toxic Cr(VI): A review
Jin, W., Du, H., Zheng, S., & Zhang, Y. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.01.130 · Cited by 306
Self-citationRong, M., Lin, L., Song, X., Wang, Y., Zhong, Y., Yan, J., Feng, Y., Zeng, X., & Chen, X. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.12.024 · Cited by 275
Jin, W., Fu, Y., Hu, M., Wang, S., & Liu, Z. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113744 · Cited by 93
Self-citation
Metadata
- Authors
- Jin, W., Wu, G., & Chen, A.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 139
- Issue
- 1
- Pages
- 235-241
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2144999025
- Cited by
- 184
- References
- 1
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive and selective electrochemical detection of chromium(vi) based on gold nanoparticle-decorated titania nanotube arrays. https://app.cochat.ai/papers/10.1039/c3an01614e
- The paper
- Jin, W., Wu, G., & Chen, A. (2014). Sensitive and selective electrochemical detection of chromium(vi) based on gold nanoparticle-decorated titania nanotube arrays. The Analyst. https://doi.org/10.1039/c3an01614e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.