A new fluorometric turn-on assay for alkaline phosphatase and inhibitor screening based on aggregation and deaggregation of tetraphenylethylene molecules
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Based on the consideration that compound 1 with a -PO3H2 group can be hydrolyzed into compound 3 which shows low solubility in aqueous solutions and thus aggregation can occur easily, a new fluorescence turn-on assay has been constructed for alkaline phosphatase (ALP) with compound 1. ALP at concentrations as low as 18 mU mL(-1) can be assayed with compound 1. Moreover, compound 1 has been successfully applied for ALP assay in living cells. Also, compound 1 is useful for screening inhibitors of ALP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Specific light-up bioprobes based on AIEgen conjugates
Liang, J., Tang, B. Z., & Liu, B. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00444b · Cited by 762
Fluorescent Sensors Based on Aggregation-Induced Emission: Recent Advances and Perspectives
Gao, M., & Tang, B. Z. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00551 · Cited by 666
Song, Z., Kwok, R. T. K., Zhao, E., He, Z., Hong, Y., Lam, J. W. Y., Liu, B., & Tang, B. Z. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am505150d · Cited by 325
Qian, Z., Chai, L., Tang, C., Huang, Y., Chen, J., & Feng, H. (2015) · Analytical Chemistry · doi:10.1021/ac504519b · Cited by 207
Liang, J., Kwok, R. T. K., Shi, H., Tang, B. Z., & Liu, B. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4026517 · Cited by 204
Gao, M., Hu, Q., Feng, G., Tang, B. Z., & Liu, B. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00345d · Cited by 201
Li, H., Kim, H., Han, J., Nguyen, V., Peng, X., & Yoon, J. (2021) · Aggregate · doi:10.1002/agt2.51 · Cited by 189
Identification of Bacteria in Water by a Fluorescent Array
Chen, W., Li, Q., Zheng, W., Hu, F., Zhang, G., Wang, Z., Zhang, D., & Jiang, X. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201407606 · Cited by 179
Self-citationLi, S.-J., Li, C.-Y., Li, Y.-F., Fei, J., Wu, P., Yang, B., Ou-Yang, J., & Nie, S.-X. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01351 · Cited by 170
Yang, R., Yan, X., Li, Y., Zhang, X., & Chen, J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b10856 · Cited by 161
Metadata
- Authors
- Gu, X., Zhang, G., Wang, Z., Liu, W., Xiao, L., & Zhang, D.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 138
- Issue
- 8
- Pages
- 2427
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1967344825
- Cited by
- 98
- References
- 1
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.