CoChat

Infrared-assisted non-ionic surfactant extraction as a green analytical preparatory technique for the rapid extraction and pre-concentration of picroside I and picroside II from Picrorhiza scrophulariiflora Pennell

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

The extraction of picroside I and picroside II from Picrorhiza scrophulariiflora Pennell using non-ionic surfactants with the assistance of infrared was investigated and the conditions for maximum yield were determined. Under optimum conditions, i.e. 10% Genapol X-080 (v/v), liquid : solid ratio of 150 : 1 (mL g−1), infrared power 200 W and infrared-assisted extraction for 4 min, the extraction yield reached the highest value. For the preconcentration of picroside I and picroside II by cloud-point extraction, the solution was incubated in a thermostatic water bath at 100 °C for 10 min, and 15% NaCl (w/v) was added to the solution to facilitate the phase separation. When compared with various polar and nonpolar solvents (pure water, ethanol, acetone, acetic ether and hexane), the extraction efficiency of 10% Genapol X-080 reached a statistically higher value (p < 0.05). By using an infrared-assisted non-ionic surfactant extraction method, the determined amounts of the picrosides in Picrorhiza scrophulariiflora Pennell were statistically higher than those extracted with conventional ultrasound-assisted extraction and heat-reflux extraction (p < 0.05). The results show that infrared-assisted non-ionic surfactant extraction is a good, efficient and green analytical preparatory technique for the rapid extraction and pre-concentration of pharmacologically active ingredients from Picrorhiza scrophulariiflora Pennell without disturbing the subsequent chromatographic analysis.

Overview

Integrity signals

Registry

Crossref · 10.1039/c3ay40135a

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 42 references

Research works printed but not linked: 1

  1. Liu, 2007, Pharmacol. Rep., 59, 573

Cited by

Metadata

Authors
Li, F., Yu, Y., Zhang, H., Liu, T., Li, Y., & Duan, G.
Affiliations
  • Fudan University (CN)
  • Dezhou University (CN)
Corresponding author
Duan, Gengli
Venue
Analytical Methods
Published
2013
Volume
5
Issue
15
Pages
3747
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W2075387490
Cited by
12
References
42
Citations by year
2022: 1 · 2021: 1 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 1
FWCI
3.15
Type
journal article
Language
en
Open access
closed
Locations
Analytical Methods (publishedVersion)
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Traditional Chinese Medicine Analysis
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Agricultural and Biological Research
Keywords
picroside I, picroside II, Picrorhiza scrophulariiflora, cloud point extraction, preconcentration, green analytical chemistry, extraction efficiency, ultrasound-assisted extraction, heat reflux extraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.