Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 295

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A cap-type Schiff base acting as a fluorescence sensor for zinc(ii) and a colorimetric sensor for iron(ii), copper(ii), and zinc(ii) in aqueous media

Kim, Kyung Beom, Kim, Hyun, Song, Eun Joo, Kim, Sumi, Noh, Insup, Kim, Cheal·2013·Dalton Transactions

Abstract

A simple and low cost chemosensor is described. This sensor could simultaneously detect three biologically important metal ions through fluorogenic (Zn(2+)) and chromogenic (Fe(2+), Cu(2+), and Zn(2+)) methods in aqueous solution. The sensor could function as a "turn-on" fluorescence receptor only to Zn(2+) ions. In addition, the sensor could be successfully applied to the detection of intracellular Zn(2+). Meanwhile, the sensor displayed an obvious red color upon selective binding with Fe(2+). Therefore, the sensor could serve as a useful tool for the discrimination of Fe(2+) from Fe(3+) in aqueous media. Moreover, the sensor also showed color changes from yellow to colorless upon selective binding with Zn(2+) and Cu(2+), respectively. The detection limit of the sensor for Cu(2+) (1.5 μM) is far below the guidelines of the World Health Organization (30 μM) as the maximum allowable copper concentration in drinking water, and therefore it is capable of being a practical system for the monitoring of Cu(2+) concentrations in aqueous samples. These results provide a new approach for selectively recognizing the most important three trace elements in the human body simultaneously, for Zn(2+) by emission spectra and Fe(2+), Cu(2+), and Zn(2+) by the naked eye.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3dt51916c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Kim, K. B., Kim, H., Song, E. J., Kim, S., Noh, I., & Kim, C.
Venue
Dalton Transactions
Published
2013
Volume
42
Issue
47
Pages
16569
ISSN
  • 1477-9226 (ISSN-L)
  • 1477-9234
OpenAlex
W1988941607
Cited by
295
References
2
FWCI
13.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A cap-type Schiff base acting as a fluorescence sensor for zinc(ii) and a colorimetric sensor for iron(ii), copper(ii), and zinc(ii) in aqueous media. https://app.cochat.ai/papers/10.1039/c3dt51916c
The paper
Kim, K. B., Kim, H., Song, E. J., Kim, S., Noh, I., & Kim, C. (2013). A cap-type Schiff base acting as a fluorescence sensor for zinc(ii) and a colorimetric sensor for iron(ii), copper(ii), and zinc(ii) in aqueous media. Dalton Transactions. https://doi.org/10.1039/c3dt51916c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.