Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Measurement techniques for piezoelectric nanogenerators

Briscoe, Joe, Jalali, Nimra, Woolliams, Peter, Stewart, Mark, Weaver, Paul M., Cain, Markys, Dunn, Steve·2013·Energy & Environmental Science

Abstract

Electromechanical energy harvesting converts mechanical energy from the environment, such as vibration or human activity, into electrical energy that can be used to power a low power electronic device. Nanostructured piezoelectric energy harvesting devices, often termed nanogenerators, have rapidly increased in measured output over recent years. With these improvements nanogenerators have the potential to compete with more traditional micro- or macroscopic energy harvesting devices based on piezoelectric ceramics such as lead zirconate titanate (PZT), polymers such as polyvinylidene fluoride (PVDF) or electrostatic, electret or electromagnetic kinetic energy harvesters. Power output from a nanogenerator is most commonly measured through open-circuit voltage and/or short-circuit current, where power may be estimated from the product of these values. Here we show that such measures do not provide a complete picture of the output of these devices, and can be misleading when attempting to compare alternative designs. In order to compare the power output from a nanogenerator, techniques must be improved in line with those used for more established technologies. We compare ZnO nanorod/poly(methyl methacrylate) (PMMA) and ZnO nanorod/poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) devices, and show that despite an open-circuit voltage nearly three times lower the ZnO/PEDOT:PSS device generates 150 times more power on an optimum load. In addition, it is shown that the peak voltage and current output can be increased by straining the device more rapidly and therefore time-averaged power, or time-integrated measures of output such as total energy or total charge should be calculated. Finally, the internal impedance of the devices is characterised to develop an understanding of their behaviour and shows a much higher internal resistance but lower capacitive impedance for the ZnO/PMMA device. It is hoped that by following more rigorous testing procedures the performance of nanostructured piezoelectric devices can be compared more realistically to other energy harvesting technologies and improvements can be rapidly driven by a more complete understanding of their behaviour.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3ee41889h

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 204

Metadata

Authors
Briscoe, J., Jalali, N., Woolliams, P., Stewart, M., Weaver, P. M., Cain, M., & Dunn, S.
Venue
Energy & Environmental Science
Published
2013
Volume
6
Issue
10
Pages
3035
ISSN
  • 1754-5692 (ISSN-L)
  • 1754-5706
OpenAlex
W2017054058
Cited by
204
References
3
FWCI
7.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement techniques for piezoelectric nanogenerators. https://app.cochat.ai/papers/10.1039/c3ee41889h
The paper
Briscoe, J., Jalali, N., Woolliams, P., Stewart, M., Weaver, P. M., Cain, M., & Dunn, S. (2013). Measurement techniques for piezoelectric nanogenerators. Energy & Environmental Science. https://doi.org/10.1039/c3ee41889h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.