A simple and versatile microfluidic cell density gradient generator for quantum dot cytotoxicity assay
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this work, a simple and versatile microfluidic cell density gradient generator was successfully developed for cytotoxicity of quantum dots (QDs) assay. The microfluidic cell density gradient generator is composed of eight parallel channels which are respectively surrounded by 1-8 microwells with optimized length and width. The cells fall into microwells by gravity and the cell densities are obviously dependent of microwell number. In a case study, HepG2 and MCF-7 cells were successfully utilized for generating cell density gradients on the microfluidic chip. The microfluidic cell density gradient generator was proved to be easily handled, cell-friendly and could be used to conduct the subsequent cell-based assay. As a proof-of-concept, QD cytotoxicity was evaluated and the results exhibited obvious cell density-dependence. For comparison, QD cytotoxicity was also investigated with a series of cell densities infused by pipette tips. Higher reproducibility was observed on the microfluidic cell density gradient generator and cell density was demonstrated to be a vital factor in cytotoxic study. With higher efficiency, controllability and reproducibility, the microfluidic cell density gradient generator could be integrated into microfluidic analysis systems to promote chip-based biological assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
Cited by
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Digital Light Processing Based Bioprinting with Composable Gradients
Wang, M., Li, W., Mille, L. S., Ching, T., Luo, Z., Tang, G., Garciamendez, C. E., Lesha, A., Hashimoto, M., & Zhang, Y. S. (2022) · Advanced Materials · doi:10.1002/adma.202107038 · Cited by 206
A review of chemical gradient systems for cell analysis
Somaweera, H., Ibraguimov, A., & Pappas, D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.008 · Cited by 98
Metadata
- Authors
- Wu, J., Chen, Q., Liu, W., & Lin, J.-M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 10
- Pages
- 1948
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2100640364
- Cited by
- 44
- References
- 1
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple and versatile microfluidic cell density gradient generator for quantum dot cytotoxicity assay. https://app.cochat.ai/papers/10.1039/c3lc00041a
- The paper
- Wu, J., Chen, Q., Liu, W., & Lin, J.-M. (2013). A simple and versatile microfluidic cell density gradient generator for quantum dot cytotoxicity assay. Lab on a Chip. https://doi.org/10.1039/c3lc00041a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.