Multiplex analysis of enzyme kinetics and inhibition by droplet microfluidics using picoinjectors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Enzyme kinetics and inhibition is important for a wide range of disciplines including pharmacology, medicine and industrial bioprocess technology. We present a novel microdroplet-based device for extensive characterization of the reaction kinetics of enzyme substrate inhibitor systems in a single experiment utilizing an integrated droplet picoinjector for bioanalysis. This device enables the scanning of multiple fluorescently-barcoded inhibitor concentrations and substrate conditions in a single, highly time-resolved experiment yielding the Michaelis constant (Km), the turnover number (kcat) and the enzyme inhibitor dissociation constants (ki, ki'). Using this device we determine Km and kcat for β-galactosidase and the fluorogenic substrate Resorufin β-D-galactopyranoside (RBG) to be 442 μM and 1070 s(-1), respectively. Furthermore, we examine the inhibitory effects of isopropyl-β-D-thiogalactopyranoside (IPTG) on β-galactosidase. This system has a number of potential applications, for example it could be used to screen inhibitors to pharmaceutically relevant enzymes and to characterize engineered enzyme variants for biofuels production, in both cases acquiring detailed information about the enzyme catalysis and enzyme inhibitor interaction at high throughput and low cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Cited by
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Single-cell screening of photosynthetic growth and lactate production by cyanobacteria
Hammar, P., Angermayr, S. A., Sjostrom, S. L., van der Meer, J., Hellingwerf, K. J., Hudson, E. P., & Joensson, H. N. (2015) · Biotechnology for Biofuels · doi:10.1186/s13068-015-0380-2 · Cited by 50
“Lactate detection assay Following incubation, the picoinjector chip [28] was used to supplement the droplets with a l-lactate assay mixture (Cayman Chemical Company).”
Self-citationNeun, S., van Vliet, L., Hollfelder, F., & Gielen, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03164 · Cited by 20
Metadata
- Authors
- Sjostrom, S. L., Joensson, H. N., & Svahn, H. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 9
- Pages
- 1754
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1993649991
- Cited by
- 89
- References
- 1
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplex analysis of enzyme kinetics and inhibition by droplet microfluidics using picoinjectors. https://app.cochat.ai/papers/10.1039/c3lc41398e
- The paper
- Sjostrom, S. L., Joensson, H. N., & Svahn, H. A. (2013). Multiplex analysis of enzyme kinetics and inhibition by droplet microfluidics using picoinjectors. Lab on a Chip. https://doi.org/10.1039/c3lc41398e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.