The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly selective gas sensor arrays based on thermally reduced graphene oxide
Abstract
The electrical properties of reduced graphene oxide (rGO) have been previously shown to be very sensitive to surface adsorbates, thus making rGO a very promising platform for highly sensitive gas sensors. However, poor selectivity of rGO-based gas sensors remains a major problem for their practical use. In this paper, we address the selectivity problem by employing an array of rGO-based integrated sensors instead of focusing on the performance of a single sensing element. Each rGO-based device in such an array has a unique sensor response due to the irregular structure of rGO films at different levels of organization, ranging from nanoscale to macroscale. The resulting rGO-based gas sensing system could reliably recognize analytes of nearly the same chemical nature. In our experiments rGO-based sensor arrays demonstrated a high selectivity that was sufficient to discriminate between different alcohols, such as methanol, ethanol and isopropanol, at a 100% success rate. We also discuss a possible sensing mechanism that provides the basis for analyte differentiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The chemistry of graphene oxide
Dreyer, D. R., Park, S., Bielawski, C. W., & Ruoff, R. S. (2010) · Chem. Soc. Rev. · doi:10.1039/b917103g · Cited by 11,653
Cited by
Self-Activated Transparent All-Graphene Gas Sensor with Endurance to Humidity and Mechanical Bending
Kim, Y. H., Kim, S. J., Kim, Y.-J., Shim, Y.-S., Kim, S. Y., Hong, B. H., & Jang, H. W. (2015) · ACS Nano · doi:10.1021/acsnano.5b04680 · Cited by 332
A 3D Chemically Modified Graphene Hydrogel for Fast, Highly Sensitive, and Selective Gas Sensor
Wu, J., Tao, K., Guo, Y., Li, Z., Wang, X., Luo, Z., Feng, S., Du, C., Chen, D., Miao, J., et al. (2017) · Advanced Science · doi:10.1002/advs.201600319 · Cited by 184
Chemically functionalized 3D graphene hydrogel for high performance gas sensing
Wu, J., Tao, K., Zhang, J., Guo, Y., Miao, J., & Norford, L. K. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta01426g · Cited by 117
Metadata
- Authors
- Lipatov, A., Varezhnikov, A., Wilson, P., Sysoev, V., Kolmakov, A., & Sinitskii, A.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 5
- Issue
- 12
- Pages
- 5426
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2167087575
- Cited by
- 307
- References
- 1
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly selective gas sensor arrays based on thermally reduced graphene oxide. https://app.cochat.ai/papers/10.1039/c3nr00747b
- The paper
- Lipatov, A., Varezhnikov, A., Wilson, P., Sysoev, V., Kolmakov, A., & Sinitskii, A. (2013). Highly selective gas sensor arrays based on thermally reduced graphene oxide. Nanoscale. https://doi.org/10.1039/c3nr00747b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.