Versatile injectable supramolecular hydrogels containing drug loaded micelles for delivery of various drugs
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this study, a novel glycol chitosan-Pluronic F127 conjugate (GC-PF127) was produced by adding a carboxyl group to the end of Pluronic F127 followed by an amidation reaction between carboxylated Pluronic F127 and glycol chitosan. Because of the hydrophobic aggregation of PPO segments in Pluronic F127, GC-PF127 self-assembles into micelles in aqueous solution at room temperature. The micelles can effectively load amphiphilic doxorubicin (DOX) and partly load negatively charged protein superoxide dismutase (SOD) at neutral pH with different mechanisms, but cannot load hydrophilic 5-fluorouracil (5-FU). The respective DOX/GC-PF127, SOD/GC-PF127, and 5-FU/GC-PF127 micelle solutions can be converted to injectable supramolecular hydrogels by addition of α-CD. The strength and dissociation rate of the hydrogels can be tuned by the α-CD concentration. The hydrogel structure can recover immediately after extrusion of the hydrogel using a syringe. The hydrogels have prolonged and almost linear release behaviours for various drugs. The hydrogels release free drugs as well as drug loaded micelles via the dissociation of the hydrogels under physiological conditions, which may enhance the targeting ability and therapeutic efficiency. The released micelles sequentially release free drugs that further prolong the release of the drugs. GC-PF127 hydrogels are versatile injectable hydrogels which can deliver various drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kozlov, M. Y., Melik-Nubarov, N. S., Batrakova, E. V., & Kabanov, A. V. (2000) · Macromolecules · doi:10.1021/ma991634x · Cited by 322
Cited by
Review of polysaccharide particle-based functional drug delivery
Barclay, T. G., Day, C. M., Petrovsky, N., & Garg, S. (2019) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2019.05.067 · Cited by 396
Supramolecular engineering of hydrogels for drug delivery
Bernhard, S., & Tibbitt, M. W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.002 · Cited by 363
Supramolecular hydrogels: synthesis, properties and their biomedical applications
Dong, R., Pang, Y., Su, Y., & Zhu, X. (2015) · Biomaterials Science · doi:10.1039/c4bm00448e · Cited by 302
Stimuli-Responsive Drug-Delivery Systems Based on Supramolecular Nanovalves
Li, Z., Song, N., & Yang, Y.-W. (2019) · Matter · doi:10.1016/j.matt.2019.05.019 · Cited by 256
Review of Stimuli-Responsive Polymers in Drug Delivery and Textile Application
CHATTERJEE, S., & Chi-leung HUI, P. (2019) · Molecules · doi:10.3390/molecules24142547 · Cited by 201
“The drug delivery system made from thermo-responsive hydrogel of glycol chitosan and PF127 by photo-polymerization was applied for delivery of doxorubicin [98].”
Method
Metadata
- Authors
- Liu, Z., & Yao, P.
- Venue
- Polym. Chem.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 5
- Issue
- 3
- Pages
- 1072-1081
- ISSN
- 1759-9954 (ISSN-L)
- 1759-9962
- OpenAlex
- W2052831512
- Cited by
- 53
- References
- 1
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.