Intrinsically stretchable and rechargeable batteries for self-powered stretchable electronics
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Stretchable electronic circuits conform to irregular three dimensional surfaces. They are formed with soft materials and contain electronic circuits, sensors, and other components. We report on a soft matter based rechargeable electrochemical power storage element for such devices. The chemistry is based on a rechargeable alkaline manganese battery concept. The cells withstand more than 700 mechanical stretch relaxation cycles up to 25% strain, with an average cell capacity of 6.5 mA h. Combined with wireless power transmission or stretchable solar cells, the rechargeable battery can be used to store and supply energy in stretchable electronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Xu, S., Zhang, Y., Cho, J., Lee, J., Huang, X., Jia, L., Fan, J. A., Su, Y., Su, J., Zhang, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms2553 · Cited by 1,404
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
25th Anniversary Article: A Soft Future: From Robots and Sensor Skin to Energy Harvesters
Bauer, S., Bauer‐Gogonea, S., Graz, I., Kaltenbrunner, M., Keplinger, C., & Schwödiauer, R. (2014) · Advanced Materials · doi:10.1002/adma.201303349 · Cited by 860
Self-citationStretchable and self-healing polymers and devices for electronic skin
Benight, S. J., Wang, C., Tok, J. B. H., & Bao, Z. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.08.001 · Cited by 617
A Self‐Healing Integrated All‐in‐One Zinc‐Ion Battery
Huang, S., Wan, F., Bi, S., Zhu, J., Niu, Z., & Chen, J. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201814653 · Cited by 498
Metadata
- Authors
- Kettlgruber, G., Kaltenbrunner, M., Siket, C. M., Moser, R., Graz, I. M., Schwödiauer, R., & Bauer, S.
- Venue
- Journal of Materials Chemistry A
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 1
- Issue
- 18
- Pages
- 5505
- ISSN
- 2050-7488 (ISSN-L)
- 2050-7496
- OpenAlex
- W2023597293
- Cited by
- 106
- References
- 3
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.