The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
One-step polymer screen-printing for microfluidic paper-based analytical device (μPAD) fabrication
Abstract
We report a simple, low-cost, one-step fabrication method for microfluidic paper-based analytical devices (μPAD) using only polystyrene and a patterned screen. The polystyrene solution applied through the screen penetrates through the paper, forming a three-dimensional hydrophobic barrier, defining a hydrophilic analysis zone. The optimal polystyrene concentration and paper types were first investigated. Adjusting polystyrene concentration allows for various types of paper to be used for successful device fabrication. Using an optimized polystyrene concentration with Whatman#4 filter paper, a linear relationship was found to exist between the design width and the printed width. The smallest hydrophilic channel and hydrophobic barrier that can be obtained are 670 ± 50 μm and 380 ± 40 μm, respectively. High device-to-device fabrication reproducibility was achieved yielding a relative standard deviation (%RSD) in the range of 1.12-2.54% (n = 64) of the measured diameter of the well-shaped fabricated test zones with a designed diameter of 5 and 7 mm. To demonstrate the significance of the fabricated μPAD, distance-based and well-based paper devices were constructed for the analysis of H2O2 and antioxidant activity, respectively. The analysis of H2O2 in real samples using distance-based measurement with CeO2 nanoparticles as the colorimetric agent produced the same results at 95% confidence level, as those obtained using KMnO4 titration. A proof-of-concept antioxidant activity determination based on the 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay was also demonstrated. The results verify that the polymer screen-printing method can be used as an alternative method for μPAD fabrication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Self-citationReview on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Paper-Based Microfluidic Devices: Emerging Themes and Applications
Yang, Y., Noviana, E., Nguyen, M. P., Geiss, B. J., Dandy, D. S., & Henry, C. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04581 · Cited by 501
Self-citationPaper-based DPPH Assay for Antioxidant Activity Analysis
Sirivibulkovit, K., Nouanthavong, S., & Sameenoi, Y. (2018) · Analytical Sciences · doi:10.2116/analsci.18p014 · Cited by 274
Self-citation
Metadata
- Authors
- Sameenoi, Y., Nongkai, P. N., Nouanthavong, S., Henry, C. S., & Nacapricha, D.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014-10-15
- Volume
- 139
- Issue
- 24
- Pages
- 6580-6588
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2131606592
- Cited by
- 178
- References
- 1
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-step polymer screen-printing for microfluidic paper-based analytical device (μPAD) fabrication. https://app.cochat.ai/papers/10.1039/c4an01624f
- The paper
- Sameenoi, Y., Nongkai, P. N., Nouanthavong, S., Henry, C. S., & Nacapricha, D. (2014). One-step polymer screen-printing for microfluidic paper-based analytical device (μPAD) fabrication. The Analyst. https://doi.org/10.1039/c4an01624f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.