The DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
DNAzyme-based biosensors and nanodevices
Abstract
DNAzymes, screened through in vitro selection, have shown great promise as molecular tools in the design of biosensors and nanodevices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Breaker, R. R., & Joyce, G. F. (1994) · Chemistry & Biology · doi:10.1016/1074-5521(94)90014-0 · Cited by 1,476
A Graphene Nanoprobe for Rapid, Sensitive, and Multicolor Fluorescent DNA Analysis
He, S., Song, B., Li, D., Zhu, C., Qi, W., Wen, Y., Wang, L., Song, S., Fang, H., & Fan, C. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901639 · Cited by 1,376
A Colorimetric Lead Biosensor Using DNAzyme-Directed Assembly of Gold Nanoparticles
Liu, J., & Lu, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034775u · Cited by 1,347
DNA-enhanced peroxidase activity of a DNA aptamer-hemin complex
Travascio, P., Li, Y., & Sen, D. (1998) · Chemistry & Biology · doi:10.1016/s1074-5521(98)90006-0 · Cited by 1,006
A Highly Sensitive and Selective Catalytic DNA Biosensor for Lead Ions
Li, J., & Lu, Y. (2000) · Journal of the American Chemical Society · doi:10.1021/ja0021316 · Cited by 704
Liu, J., & Lu, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0717358 · Cited by 647
Cited by
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Hildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
DNA Functional Materials Assembled from Branched DNA: Design, Synthesis, and Applications
Dong, Y., Yao, C., Zhu, Y., Yang, L., Luo, D., & Yang, D. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00294 · Cited by 533
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Metadata
- Authors
- Gong, L., Zhao, Z., Lv, Y.-F., Huan, S.-Y., Fu, T., Zhang, X.-B., Shen, G.-L., & Yu, R.-Q.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 51
- Issue
- 6
- Pages
- 979-995
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W1992015169
- Cited by
- 321
- References
- 89
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DNAzyme-based biosensors and nanodevices. https://app.cochat.ai/papers/10.1039/c4cc06855f
- The paper
- Gong, L., Zhao, Z., Lv, Y.-F., Huan, S.-Y., Fu, T., Zhang, X.-B., Shen, G.-L., & Yu, R.-Q. (2015). DNAzyme-based biosensors and nanodevices. Chemical Communications. https://doi.org/10.1039/c4cc06855f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.