The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index; 1 of the 32 sources its claims cite were checked for support.
Hydrogen or batteries for grid storage? A net energy analysis
Open accessAbstract
Storing electrical energy in hydrogen requires less manufacturing energy than batteries, per unit of energy dispatched over the system's lifetime.
Overview
CoChat Summary
TL;DR
This net energy analysis compares a regenerative hydrogen fuel cell (RHFC) system with batteries for grid storage. The reference RHFC has a higher electrical energy stored on invested (ESOIe) ratio than lithium-ion batteries, but a much lower round-trip and overall energy efficiency.
Key findings
- The reference RHFC system has an ESOIe ratio of 59, higher than lithium-ion batteries (ESOIe = 35), but lower than pumped hydro (830) and compressed air/natural gas (1100).
- The RHFC reference case has a round-trip efficiency of 0.30 and overall energy efficiency of 0.30, versus 0.83 for lithium-ion batteries; lithium-ion round-trip efficiencies are 75–90%.
- Sensitivity: doubling fuel cell stack lifetime, increasing fuel cell efficiency from 47% to 57%, or reducing fuel cell stack energy intensity from 1.7 × 10^5 to 1.1 × 10^5 MJel/MWel would raise the ESOIe ratio to 68; a 30,000 h stack lifetime gives 72, and 50,000 h with 0.60 efficiency gives 110.
- For wind overgeneration, RHFC storage achieves the same [EROI]grid as batteries when storing overgeneration from wind turbines; for photovoltaic overgeneration, RHFC is less favorable than lithium-ion or sodium-sulfur batteries but preferable to curtailment.
Methods
- Net energy analysis using ESOIe = lifetime electrical energy dispatched / embodied electrical energy, and overall energy efficiency Z* = Eout / (Eemb + Ein).
- Reference case: hypothetical wind farm with 5 MW overgeneration for 8 h/day, 34-year service life, alkaline water electrolyzer at 70% efficiency and 100,000 h stack lifetime, PEM fuel cell at 47% efficiency and 10,000 h stack lifetime, 3 days of hydrogen storage, and 2.6 MW fuel cell power.
- Data were compiled from literature; alkaline electrolyzer stack energy intensity was approximated from an alkaline fuel cell LCI, and battery/geologic storage ESOIe ratios were revised from Barnhart and Benson using cradle-to-gate embodied energy.
Limitations
- The paper states the largest uncertainty is the alkaline electrolyzer stack energy intensity; no peer-reviewed LCI is available for alkaline water electrolyzers, and balance-of-system data are lacking for alkaline electrolyzers and limited for PEMFCs.
- The paper states it assumes the electrolyzer and fuel cell always operate at 100% rated power, considers only the AWE-PEMFC configuration, and excludes resource constraints such as platinum availability.
- Evident from the text: the reference case is hypothetical, parameter values come from varied sources, and the analysis does not model cost, market structure, or investment behavior.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




![Fig. 5 A generating facility with [EROI]gen may experience curtailment, resulting in an overall EROI of [EROI]curt. Alternatively, the overgeneration may be routed through a storage facility, resulting in an overall EROI of [EROI]grid.](/paper-figures/c5cd3159b84d4a0ba14f63e6ac7909cb/hydrogen-or-batteries-for-grid-storage-a-net-energy-analysis-figure-5.png)



Verification
Claims the paper makes
0 Valid · 4 Not valid · 21 Not checked · 99 Own results and interpretations
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“A RHFC energy storage facility with these technical characteristics and configuration has an ESOI e ratio of 59 (from eqn (9)).”
- Also stated in: § 4 Discussion · plain
“Energy storage in hydrogen, using the reference case RHFC system, has a ESOI e ratio of 59.”
§ Hydrogen or batteries for grid storage? A net energy analysis † > 3.1 ESOI e ratio of a regenerative hydrogen fuel cell
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § 4 Discussion · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“It is an important factor governing the net energy balance of a RHFC system (Fig. 3).”
§ Hydrogen or batteries for grid storage? A net energy analysis † > 4.3 Energy-to-power ratio and implications for seasonal storage
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“At small values of R, technology advances such as improvements in fuel cell lifetime and efficiency can significantly increase the ESOI e ratio of the RHFC system.”
§ Hydrogen or batteries for grid storage? A net energy analysis † > 3.2 ESOI e sensitivity analysis
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“the short cell stack lifetime requires seven replacements of the fuel cell stack during the service lifetime of the RHFC system.”
§ Hydrogen or batteries for grid storage? A net energy analysis † > 4.2 Key technical parameters and implications for research
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“From eqn (21), the reference case RHFC system has a round-trip efficiency of Z system = 0.30.”
§ Hydrogen or batteries for grid storage? A net energy analysis † > 3.1 ESOI e ratio of a regenerative hydrogen fuel cell
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
88 more claims
Create a free account to see all 124 claims and to verify the 2 references still open.
- It may state two separate claims as one. 24
- Probably not a substantial claim. 8
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Energy storage is paramount in electric and hybrid vehicles, in green but intermittent energy sources, and in smart grids in general.”
From Lithium recovery from brines: A vital raw material for green energies with a potential environmental impact in its mining and processing (2018) · cites this paper as Pellow et al., 2015
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“| LIB b | 677 | 64 | 752 | 35 | 0.83 |”
§ Hydrogen or batteries for grid storage? A net energy analysis † > Analysis Energy & Environmental Science
Reported 35 · recomputed 10.578125
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“which is 3.02 Â 10 5 MJ at Z lyz = 0.7 (equal to 84 MW h or 251 kg H 2 [LHV basis]).”
§ Hydrogen or batteries for grid storage? A net energy analysis † > 3.1 ESOI e ratio of a regenerative hydrogen fuel cell
Reported 251 · recomputed 2512.479201
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“Ref. 12 specified the technologies types of both the electrolyzer and the fuel cell for 38 RHFC systems.These include 15 AWE-PEMFC systems; 10 PEMWE-PEMFC systems; four AWE-ICE systems; four AWE-CHP systems; two AWE-AFC systems; one PEMWE-ICE system; and one AWE-phosphoric acid fuel cell system.”
§ Hydrogen or batteries for grid storage? A net energy analysis † > Analysis Energy & Environmental Science
Reported 38 · recomputed 37
Citations
Cites
Electrocatalyst approaches and challenges for automotive fuel cells
Debe, M. K. (2012) · Nature · doi:10.1038/nature11115 · Cited by 5,885
Wang, Y., Chen, K. S., Mishler, J., Cho, S. C., & Adroher, X. C. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.09.030 · Cited by 3,329
IPCC Special Report on Renewable Energy Sources and Climate Change Mitigation
Revel, D. (2011) · OpenEdition (OpenEdition) · doi:10.58079/o8wx · Cited by 2,175
Electrical energy storage systems: A comparative life cycle cost analysis
Zakeri, B., & Syri, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.011 · Cited by 1,861
An overview of fuel cell technology: Fundamentals and applications
Sharaf, O. Z., & Orhan, M. F. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.01.012 · Cited by 1,859
International Energy Agency (2012) · World Energy Outlook · doi:10.1787/weo-2012-en · Cited by 1,219
The hydrogen-fueled internal combustion engine: a technical review
WHITE, C., STEEPER, R., & LUTZ, A. (2006) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2005.12.001 · Cited by 1,197
Gahleitner, G. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2012.12.010 · Cited by 1,174
Energy storage for mitigating the variability of renewable electricity sources: An updated review
Beaudin, M., Zareipour, H., Schellenberglabe, A., & Rosehart, W. (2010) · Energy for Sustainable Development · doi:10.1016/j.esd.2010.09.007 · Cited by 1,042
Denholm, P., & Hand, M. (2011) · Energy Policy · doi:10.1016/j.enpol.2011.01.019 · Cited by 947
Research works printed but not linked: 3
- M. Hand , S.Baldwin, E.DeMeo, J.Reilly, T.Mai, D.Arent, G.Porro, M.Meshek and D.Sandor, Renewable Electricity Futures Study, National Renewable Energy Laboratory, Golden, CO, 2012
- B. Hobein and R.Kruger, in Hydrogen and Fuel Cells – Fundamentals, Technologies, Applications, ed. D. Stolten, Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim, 2010, ch. 18
- V. Karakoussis , M.Leach, R.van der Vorst, D.Hart, J.Lane, P.Pearson and J.Kilner, Environmental Emissions of SOFC and SPFC System Manufacture and Disposal, Imperial College of Science, Technology and Medicine Technical Report F/01/00164/REP, 2000
Cited by
Lithium-ion batteries: outlook on present, future, and hybridized technologies
Kim, T., Song, W., Son, D.-Y., Ono, L. K., & Qi, Y. (2019) · Journal of Materials Chemistry A · doi:10.1039/c8ta10513h · Cited by 2,479
Future cost and performance of water electrolysis: An expert elicitation study
Schmidt, O., Gambhir, A., Staffell, I., Hawkes, A., Nelson, J., & Few, S. (2017) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2017.10.045 · Cited by 2,067
Alkaline Water Electrolysis Powered by Renewable Energy: A Review
Brauns, J., & Turek, T. (2020) · Processes · doi:10.3390/pr8020248 · Cited by 817
Feng, Q., Yuan, X., Liu, G., Wei, B., Zhang, Z., Li, H., & Wang, H. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.09.006 · Cited by 776
Duan, C., Kee, R., Zhu, H., Sullivan, N., Zhu, L., Bian, L., Jennings, D., & O’Hayre, R. (2019) · Nature Energy · doi:10.1038/s41560-019-0333-2 · Cited by 764
Metadata
- Authors
- Pellow, M. A., Emmott, C. J. M., Barnhart, C. J., & Benson, S. M.
- Affiliations
- Stanford University (US)
- Imperial College London (GB)
- Western Washington University (US)
- Corresponding author
- Pellow, Matthew A.
- Venue
- Energy & Environmental Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 8
- Issue
- 7
- Pages
- 1938-1952
- ISSN
- 1754-5692 (ISSN-L)
- 1754-5706
- OpenAlex
- W2171249747
- Semantic Scholar
- 5a249f85645a11479e9cb8d0cd404c93a67c715c
- Cited by
- 450
- References
- 50
- Citations by year
- 2026: 41 · 2025: 55 · 2024: 59 · 2023: 55 · 2022: 45 · 2021: 51 · 2020: 43 · 2019: 33 · 2018: 27 · 2017: 24 · 2016: 13 · 2015: 4
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Energy & Environmental Science (publishedVersion, cc-by)
- Funders
- Clemson University
- Technische Universität München
- EIT Climate-KIC
- Topics
- Physical Sciences › Energy › Energy Engineering and Power Technology › Hybrid Renewable Energy Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
- Keywords
- hydrogen energy storage, battery energy storage, grid storage, net energy analysis, energy dispatch, energy storage technology comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›