Cell patterning with a heptagon acoustic tweezer – application in neurite guidance

Open access

Abstract

Accurate control over positioning of cells is a highly desirable feature in tissue engineering applications since it allows, for example, population of substrates in a controlled fashion, rather than relying on random seeding. Current methods to achieve a differential distribution of cells mostly use passive patterning methods to change chemical, mechanical or topographic properties of surfaces, making areas differentially permissive to the adhesion of cells. However, these methods have no ad hoc control over the actual deposition of cells. Direct patterning methods like bioprinting offer good control over cell position, but require sophisticated instrumentation and are often cost- and time-intensive. Here, we present a novel electronically controlled method of generating dynamic cell patterns by acoustic trapping of cells at a user-determined position, with a heptagonal acoustic tweezer device. We demonstrate the capability of the device to create complex patterns of cells using the device's ability to re-position acoustic traps by using a phase shift in the acoustic wave, and by switching the configuration of active piezoelectric transducers. Furthermore, we show that by arranging Schwann cells from neonatal rats in a linear pattern we are able to create Bands of Büngner-like structures on a non-structured surface and demonstrate that these features are able to guide neurite outgrowth from neonatal rat dorsal root ganglia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c4lc00436a

Cites

49 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Research works printed but not linked: 1

  1. Zhang, 2013, J. Mater. Sci.: Mater. Med., 24, 1767

Cited by

Sorted by citations

See all 101

Metadata

Authors
Gesellchen, F., Bernassau, A. L., Déjardin, T., Cumming, D. R. S., & Riehle, M. O.
Affiliations
University of Glasgow (GB)
Corresponding author
Riehle, M. O.
Venue
Lab Chip
Published
2014
Volume
14
Issue
13
Pages
2266-2275
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2104860111
Cited by
98
References
52
Citations by year
2026: 2 · 2025: 3 · 2024: 6 · 2023: 9 · 2022: 9 · 2021: 8 · 2020: 14 · 2019: 11 · 2018: 9 · 2017: 11 · 2016: 9 · 2015: 5 · 2014: 2
FWCI
4.67
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Lab on a Chip (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (acceptedVersion)
Funders
  • Engineering and Physical Sciences Research Council (EP/G011494/1)
  • University Of Glasgow (Lord Kelvin Adam Smith Fellowship in Sensor System)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
Keywords
cell patterning, neurite guidance, Schwann cells, dorsal root ganglia, piezoelectric transducers, cell positioning, tissue engineering
MeSH terms
Animals, Dendrites, Ganglia, Spinal, Schwann Cells, Sound, Rats, Sprague-Dawley, Coculture Techniques, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review