Facile synthesis of novel 3D nanoflower-like CuxO/multilayer graphene composites for room temperature NOx gas sensor application
The DOI matches its Crossref record.
Abstract
3D nanoflower-like CuxO/multilayer graphene composites (CuMGCs) have been successfully synthesized as a new type of room temperature NOx gas sensor. Firstly, the expanded graphite (EG) was activated by KOH and many moderate functional groups were generated; secondly, Cu(CH3COO)2 and CTAB underwent full infusion into the interlayers of activated EG (aEG) by means of a vacuum-assisted technique and then reacted with the functional groups of aEG accompanied by the exfoliation of aEG via reflux. Eventually, the 3D nanoflower consisting of 5-9 nm CuxO nanoparticles homogeneously grow in situ on aEG. The KOH activation of EG plays a key role in the uniform formation of CuMGCs. When being used as gas sensors for detection of NOx, the CuMGCs achieved a higher response at room temperature than that of the corresponding CuxO. In detail, the CuMGCs show a higher NOx gas sensing performance with low detection limit of 97 ppb, high gas response of 95.1% and short response time of 9.6 s to 97.0 ppm NOx at room temperature. Meanwhile, the CuMGC sensor presents a favorable linearity, good selectivity and stability. The enhancement of the sensing response is mainly attributed to the improved conductivity of the CuMGCs. A series of Mott-Schottky and EIS measurements demonstrated that the CuMGCs have much higher donor densities than CuxO and can easily capture and migrate electrons from the conduction band, resulting in the enhancement of electrical conductivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Recent advances in graphene based gas sensors
Varghese, S. S., Lonkar, S., Singh, K. K., Swaminathan, S., & Abdala, A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.04.062 · Cited by 890
Two‐Dimensional Nanostructured Materials for Gas Sensing
Liu, X., Ma, T., Pinna, N., & Zhang, J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702168 · Cited by 851
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
2D Materials for Gas Sensing Applications: A Review on Graphene Oxide, MoS2, WS2 and Phosphorene
Donarelli, M., & Ottaviano, L. (2018) · Sensors · doi:10.3390/s18113638 · Cited by 644
Zhang, D., Chang, H., Li, P., Liu, R., & Xue, Q. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.11.024 · Cited by 431
Gas Sensors Based on Chemi-Resistive Hybrid Functional Nanomaterials
Jian, Y., Hu, W., Zhao, Z., Cheng, P., Haick, H., Yao, M., & Wu, W. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0407-5 · Cited by 429
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Graphene-based hybrids for chemiresistive gas sensors
Meng, F.-L., Guo, Z., & Huang, X.-J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.008 · Cited by 337
Resistive-type hydrogen gas sensor based on TiO2: A review
Li, Z., Yao, Z., Haidry, A. A., Plecenik, T., Xie, L., Sun, L., & Fatima, Q. (2018) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2018.09.051 · Cited by 329
Self-citationA room-temperature NO2 gas sensor based on CuO nanoflakes modified with rGO nanosheets
Bai, H., Guo, H., Wang, J., Dong, Y., Liu, B., Xie, Z., Guo, F., Chen, D., Zhang, R., & Zheng, Y. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129783 · Cited by 293
Self-citationXia, Y., Wang, J., Xu, J.-L., Li, X., Xie, D., Xiang, L., & Komarneni, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b12501 · Cited by 245
Self-citationRecent development in nanocarbon materials for gas sensor applications
Xiao, Z., Kong, L. B., Ruan, S., Li, X., Yu, S., Li, X., Jiang, Y., Yao, Z., Ye, S., Wang, C., et al. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.07.040 · Cited by 192
Graphene-enhanced metal oxide gas sensors at room temperature: a review
Sun, D., Luo, Y., Debliquy, M., & Zhang, C. (2018) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.9.264 · Cited by 181
Metadata
- Authors
- Yang, Y., Tian, C., Wang, J., Sun, L., Shi, K., Zhou, W., & Fu, H.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 6
- Issue
- 13
- Pages
- 7369
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2105031224
- Cited by
- 140
- References
- 0
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.