The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Carbon flow electrodes for continuous operation of capacitive deionization and capacitive mixing energy generation
Open accessAbstract
Capacitive technologies, such as capacitive deionization and energy harvesting based on mixing energy (“capmix” and “CO2 energy”), are characterized by intermittent operation: phases of ion electrosorption from the water are followed by system regeneration. From a system application point of view, continuous operation has many advantages, to optimize performance, to simplify system operation, and ultimately to lower costs. In our study, we investigate as a step towards second generation capacitive technologies the potential of continuous operation of capacitive deionization and energy harvesting devices, enabled by carbon flow electrodes using a suspension based on conventional activated carbon powders. We show how the water residence time and mass loading of carbon in the suspension influence system performance. The efficiency and kinetics of the continuous salt removal process can be improved by optimizing device operation, without using less common or highly elaborate novel materials. We demonstrate, for the first time, continuous energy generation via capacitive mixing technology using differences in water salinity, and differences in gas phase CO2 concentration. Using a novel design of cylindrical ion exchange membranes serving as flow channels, we continuously extract energy from available concentration differences that otherwise would remain unused. These results may contribute to establishing a sustainable energy strategy when implementing energy extraction for sources such as CO2-emissions from power plants based on fossil fuels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Desalination via a New Membrane Capacitive Deionization Process Utilizing Flow-Electrodes
Jeon, S.-I., Park, H.-R., Yeo, J.-G., Yang, S., Cho, C. H., Han, M. H., & Kim, D. K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee24443a · Cited by 727
Zhao, R., Porada, S., Biesheuvel, P. M., & van der Wal, A. (2013) · Desalination · doi:10.1016/j.desal.2013.08.017 · Cited by 383
Cited by
Zhang, C., Ma, J., Wu, L., Sun, J., Wang, L., Li, T., & Waite, T. D. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c06552 · Cited by 323
Energy Efficiency of Capacitive Deionization
Wang, L., Dykstra, J. E., & Lin, S. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b04858 · Cited by 292
Folaranmi, G., Bechelany, M., Sistat, P., Cretin, M., & Zaviska, F. (2020) · Membranes · doi:10.3390/membranes10050096 · Cited by 149
Choi, S., Chang, B., Kang, J. H., Diallo, M. S., & Choi, J. W. (2017) · Journal of Membrane Science · doi:10.1016/j.memsci.2017.07.043 · Cited by 60
Saif, H. M., Crespo, J. G., & Pawlowski, S. (2023) · Journal of Membrane Science Letters · doi:10.1016/j.memlet.2023.100059 · Cited by 35
Metadata
- Authors
- Porada, S., Weingarth, D., Hamelers, H. V. M., Bryjak, M., Presser, V., & Biesheuvel, P. M.
- Venue
- Journal of Materials Chemistry A
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 2
- Issue
- 24
- Pages
- 9313
- ISSN
- 2050-7488 (ISSN-L)
- 2050-7496
- OpenAlex
- W2140379557
- Cited by
- 308
- References
- 2
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon flow electrodes for continuous operation of capacitive deionization and capacitive mixing energy generation. https://app.cochat.ai/papers/10.1039/c4ta01783h
- The paper
- Porada, S., Weingarth, D., Hamelers, H. V. M., Bryjak, M., Presser, V., & Biesheuvel, P. M. (2014). Carbon flow electrodes for continuous operation of capacitive deionization and capacitive mixing energy generation. Journal of Materials Chemistry A. https://doi.org/10.1039/c4ta01783h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.