The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Holey reduced graphene oxide nanosheets for high performance room temperature gas sensing
Abstract
Holey reduced graphene oxide (RGO) sheets were formed by one-pot hydrothermal treatment of graphene oxide (GO) at a dilute concentration (0.25 mg ml−1). The holes were generated through a carbon gasification reaction with the steam created in the hydrothermal system. The perforated structure provides not only sufficient active sites for molecule adsorption, but also provides channels for gas diffusion. Thus, the sensor based on the networks, which were constructed from the perforated RGO nanosheets, exhibited an enhanced sensitivity to toxic NO2 gas at ppb level, surpassing the performance of the annealed RGO. Interestingly, the polarity of the holey RGO transformed from p-mode to n-mode after exposure to NH3 and a repeatable sensing to NH3 within-mode nanoporous RGO was observed. The results demonstrate that structure modification of RGO through perforation is a promising approach for improving the sensing performance. Furthermore, the perforated RGO obtained through a one-pot hydrothermal process can be used for high performance gas sensing at room temperature, demonstrating its practical application in flexible and wearable gas sensors based on the good mechanical flexibility of RGO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization of partially reduced graphene oxide as room temperature sensor for H2
Zhang, L.-S., Wang, W. D., Liang, X.-Q., Chu, W.-S., Song, W.-G., Wang, W., & Wu, Z.-Y. (2011) · Nanoscale · doi:10.1039/c1nr10187k · Cited by 77
Cited by
Recent advances in graphene based gas sensors
Varghese, S. S., Lonkar, S., Singh, K. K., Swaminathan, S., & Abdala, A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.04.062 · Cited by 890
Yang, S., Jiang, C., & Wei, S.-H. (2017) · Applied Physics Reviews · doi:10.1063/1.4983310 · Cited by 876
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
2D Materials for Gas Sensing Applications: A Review on Graphene Oxide, MoS2, WS2 and Phosphorene
Donarelli, M., & Ottaviano, L. (2018) · Sensors · doi:10.3390/s18113638 · Cited by 644
Two-Dimensional Materials for Sensing: Graphene and Beyond
Varghese, S., Varghese, S., Swaminathan, S., Singh, K., & Mittal, V. (2015) · Electronics · doi:10.3390/electronics4030651 · Cited by 466
Metadata
- Authors
- Wang, D. H., Hu, Y., Zhao, J. J., Zeng, L. L., Tao, X. M., & Chen, W.
- Venue
- J. Mater. Chem. A
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014-08-27
- Volume
- 2
- Issue
- 41
- Pages
- 17415-17420
- ISSN
- 2050-7488 (ISSN-L)
- 2050-7496
- OpenAlex
- W2112955803
- Cited by
- 159
- References
- 1
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holey reduced graphene oxide nanosheets for high performance room temperature gas sensing. https://app.cochat.ai/papers/10.1039/c4ta03740e
- The paper
- Wang, D. H., Hu, Y., Zhao, J. J., Zeng, L. L., Tao, X. M., & Chen, W. (2014). Holey reduced graphene oxide nanosheets for high performance room temperature gas sensing. J. Mater. Chem. A. https://doi.org/10.1039/c4ta03740e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.