The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optical sensing of biological, chemical and ionic species through aggregation of plasmonic nanoparticles
Abstract
Plasmonic nanoparticles made of gold and silver have attracted a great deal of research attention in various fields, such as biosensors, imaging, therapy, nanophotonics, catalysis and light harvesting due to their unique optical and electronic properties. Plasmonic nanoparticle colloids may exhibit strong colours in the visible region due to localized surface plasmon resonances, whereas their aggregates exhibit different linear and nonlinear optical properties. Therefore, a smart design of chemical interactions between analytes and the nanoparticles surface may lead to gradual optical changes, which can be probed by various sensing methods, allowing quantitative analyte detection. A significant amount of research has been carried out toward the development of plasmonic sensors based on analyte-induced aggregation of Au or Ag nanoparticles, and the sensitivity and selectivity of such plasmonic biosensors have been greatly improved over the years. In this feature article, we summarize different design strategies that have been employed to induce the aggregation of plasmonic nanoparticles upon the addition of various analytes such as DNA, proteins, organic molecules and inorganic ions. We introduce various optical assays, such as colorimetry, surface-enhanced Raman scattering, two-photon photoluminescence, dynamic light scattering, hyper-Rayleigh scattering and chiroptical activity. From the discussion, it can be concluded that plasmonic sensors based on nanoparticle aggregation offer simple, highly sensitive and selective detection of various analytes. Finally, we discuss some of the future directions of plasmonic nanosensors toward device integration for practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cited by
Polyvinylpyrrolidone (PVP) in nanoparticle synthesis
Koczkur, K. M., Mourdikoudis, S., Polavarapu, L., & Skrabalak, S. E. (2015) · Dalton Transactions · doi:10.1039/c5dt02964c · Cited by 1,781
Self-citationWearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Nanoparticle-based optical sensor arrays
Bigdeli, A., Ghasemi, F., Golmohammadi, H., Abbasi-Moayed, S., Nejad, M. A. F., Fahimi-Kashani, N., Jafarinejad, S., Shahrajabian, M., & Hormozi-Nezhad, M. R. (2017) · Nanoscale · doi:10.1039/c7nr03311g · Cited by 265
Metadata
- Authors
- Polavarapu, L., Pérez-Juste, J., Xu, Q.-H., & Liz-Marzán, L. M.
- Venue
- Journal of Materials Chemistry C
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014-07-16
- Volume
- 2
- Issue
- 36
- Pages
- 7460
- ISSN
- 2050-7526 (ISSN-L)
- 2050-7534
- OpenAlex
- W2146282580
- Cited by
- 239
- References
- 3
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.