Isolation of circulating tumour cells by physical means in a microfluidic device: a review
The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Isolation and enumeration of circulating tumour cells (CTCs) from human blood has a huge significance in diagnosis and prognosis of cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Global burden of cancers attributable to infections in 2008: a review and synthetic analysis
de Martel, C., Ferlay, J., Franceschi, S., Vignat, J., Bray, F., Forman, D., & Plummer, M. (2012) · The Lancet Oncology · doi:10.1016/s1470-2045(12)70137-7 · Cited by 2,534
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Circulating Tumor Cells: Liquid Biopsy of Cancer
Alix-Panabières, C., & Pantel, K. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.194258 · Cited by 1,134
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
The Motion and Precipitation of Suspensoids in Divergent Electric Fields
Pohl, H. A. (1951) · Journal of Applied Physics · doi:10.1063/1.1700065 · Cited by 1,097
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Research works printed but not linked: 7
- Ali, 2009, Int. J. Mech. Mater. Eng., 4, 93
- Pilnam Kim, 2008, BioChip J., 2, 1
- Chunxiao Hu, 2013, PLoS One, 8, 17
- Lo, 2012, J. Bioprocess. Biotech., 02, 1
- Wenjie Sun, 2013, PLoS One, 8, 9
- T. F. Takeshi Hayakawa , K.Ito, and F.Arai, Micro Electro Mechanical Systems (MEMS), 2014 IEEE 27th International Conference, 2014, p. 4
- Low, 2015, BioMed Res. Int., 2015, 239362
Cited by
Clogging of microfluidic systems
Dressaire, E., & Sauret, A. (2017) · Soft Matter · doi:10.1039/c6sm01879c · Cited by 370
Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
Sriram, G., Bhat, M. P., Patil, P., Uthappa, U. T., Jung, H.-Y., Altalhi, T., Kumeria, T., Aminabhavi, T. M., Pai, R. K., Madhuprasad, et al. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.06.005 · Cited by 204
Self-citationA review of microfluidic approaches for investigating cancer extravasation during metastasis
Ma, Y.-H. V., Middleton, K., You, L., & Sun, Y. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.104 · Cited by 154
Lab-on-a-Chip Platforms for Detection of Cardiovascular Disease and Cancer Biomarkers
Wu, J., Dong, M., Santos, S. C., Rigatto, C., Liu, Y., & Lin, F. (2017) · Sensors · doi:10.3390/s17122934 · Cited by 96
Farshchi, F., & Hasanzadeh, M. (2020) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2020.111153 · Cited by 85
Metadata
- Authors
- Patil, P., Madhuprasad, M., Kumeria, T., Losic, D., & Kurkuri, M.
- Affiliations
- Jain University (IN)
- Centre for Nano and Material Sciences
- University of California San Diego (US)
- School of Chemical Engineering
- Corresponding author
- Kurkuri, Mahaveer
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 5
- Issue
- 109
- Pages
- 89745-89762
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W1849634749
- Cited by
- 47
- References
- 95
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 5 · 2023: 5 · 2022: 2 · 2021: 6 · 2020: 5 · 2019: 4 · 2018: 9 · 2017: 5 · 2016: 2
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- RSC Advances (publishedVersion)
- Funders
- University of Ottawa
- Jain University
- Department of Science and Technology, Ministry of Science and Technology, India
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- circulating tumor cells, CTC isolation, microfluidics, physical separation, cancer diagnosis, cancer prognosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Isolation of circulating tumour cells by physical means in a microfluidic device: a review. https://app.cochat.ai/papers/10.1039/c5ra16489c
- The paper
- Patil, P., Madhuprasad, M., Kumeria, T., Losic, D., & Kurkuri, M. (2015). Isolation of circulating tumour cells by physical means in a microfluidic device: a review. RSC Advances. https://doi.org/10.1039/c5ra16489c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.