Cited by 15Analytical chemistry methods developmentHeavy Metals in PlantsSeaweed-derived Bioactive Compounds

A Procedure for the Quantification of Total Iodine by Inductively Coupled Plasma Mass Spectrometry, and Its Application to the Determination of Iodine in Algae Sampled in the Lagoon of Venice

Badocco, D., Di Marco, V., Piovan, A., Caniato, R., Pastore, P.·2016·Analytical Methods

Abstract

A new ICP-MS procedure was set up, and it was used to perform iodine biomonitoring in seaweeds growing in Venice.

Integrity signals

Registry

Crossref · 10.1039/c6ay02204a

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 37 · Cited by 15

Authors
Badocco, D., Di Marco, V., Piovan, A., Caniato, R., & Pastore, P.
Affiliations
  • University of Padua (IT)
  • Department of Chemical Sciences
Corresponding author
Pastore, P.
Venue
Analytical Methods
Published
2016
Volume
8
Issue
41
Pages
7545-7551
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W2519368989
Cited by
15
References
37
Citations by year
2026: 3 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 2 · 2018: 1 · 2017: 1
FWCI
0.53
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Methods (publishedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
Funders
Ministero dell'Università e della Ricerca
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Heavy Metals in Plants
  • Life Sciences › Agricultural and Biological Sciences › Aquatic Science › Seaweed-derived Bioactive Compounds
Keywords
iodine determination, seaweed, algae, biomonitoring, Venice Lagoon

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review