A lab-on-a-chip device for investigating the fusion process of olfactory ensheathing cell spheroids
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We report a lab-on-a-chip device for trapping and fusion of three-dimensional spheroids that assist transplantation therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional cell culture: the missing link in drug discovery
Breslin, S., & O’Driscoll, L. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2012.10.003 · Cited by 1,332
The differential adhesion hypothesis: a direct evaluation
Foty, R. A., & Steinberg, M. S. (2005) · Developmental Biology · doi:10.1016/j.ydbio.2004.11.012 · Cited by 908
Fusion of uniluminal vascular spheroids: A model for assembly of blood vessels
Fleming, P. A., Argraves, W. S., Gentile, C., Neagu, A., Forgacs, G., & Drake, C. J. (2010) · Developmental Dynamics · doi:10.1002/dvdy.22161 · Cited by 123
Cited by
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
“Some other devices under investigation are culture-only chips, meaning that spheroid formation must first proceed using different methods outside the chip, before introduction to the chip for culture and drug efficacy testing [6, 8, 87].”
BackgroundMethodInfluentialSelf-citationTrujillo-de Santiago, G., Flores-Garza, B. G., Tavares-Negrete, J. A., Lara-Mayorga, I. M., González-Gamboa, I., Zhang, Y. S., Rojas-Martínez, A., Ortiz-López, R., & Álvarez, M. M. (2019) · Materials · doi:10.3390/ma12182945 · Cited by 184
“Several other papers have illustrated the use of CFD to improve the hydraulic design of lab-on-chip systems [221] and organ-on-chip systems [69,222], including tumor-on-chip devices.”
BackgroundRecent advances and current challenges in magnetophoresis based micro magnetofluidics
Munaz, A., Shiddiky, M. J. A., & Nguyen, N.-T. (2018) · Biomicrofluidics · doi:10.1063/1.5035388 · Cited by 164
Self-citationKim, T. Y., Kofron, C. M., King, M. E., Markes, A. R., Okundaye, A. O., Qu, Z., Mende, U., & Choi, B.-R. (2018) · PLOS ONE · doi:10.1371/journal.pone.0196714 · Cited by 57
Magnetofluidic micromixer based on a complex rotating magnetic field
Munaz, A., Kamble, H., Shiddiky, M. J. A., & Nguyen, N.-T. (2017) · RSC Advances · doi:10.1039/c7ra08073e · Cited by 23
Self-citation
Metadata
- Authors
- Munaz, A., Vadivelu, R. K., John, J. A. S., & Nguyen, N.-T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 16
- Issue
- 15
- Pages
- 2946-2954
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2461771466
- Cited by
- 20
- References
- 3
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A lab-on-a-chip device for investigating the fusion process of olfactory ensheathing cell spheroids. https://app.cochat.ai/papers/10.1039/c6lc00815a
- The paper
- Munaz, A., Vadivelu, R. K., John, J. A. S., & Nguyen, N.-T. (2016). A lab-on-a-chip device for investigating the fusion process of olfactory ensheathing cell spheroids. Lab on a Chip. https://doi.org/10.1039/c6lc00815a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.