The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Peroxidase-like activity of the Co3O4nanoparticles used for biodetection and evaluation of antioxidant behavior
Abstract
Nanostructured enzyme mimics are of great interest as promising alternatives to artificial enzymes for biomedical and catalytic applications. Studying the chemical interactions between antioxidants and nano-enzymes may result in a better understanding of the antioxidant capability of antioxidants and may help improve the function of artificial enzymes to better mimic natural enzymes. In this study, using Co3O4 nanoparticles (NPs) as peroxidase mimics to catalyze the oxidation of chromophoric substrates by H2O2, we developed a platform that acts as a biosensor for hydrogen peroxide and glucose and that can study the inhibitory effects of natural antioxidants on peroxidase mimics. This method can be applied specifically to glucose detection in real samples. Three natural antioxidants, gallic acid (GA), tannic acid (TA), and ascorbic acid (AA), were compared for their antioxidant capabilities. We found that these three antioxidants efficiently inhibit peroxidase-like activity with concentration dependence. The antioxidants showed different efficiencies, in the following order: tannic acid > gallic acid > ascorbic acid. They also showed distinct modes of inhibition based on different interaction mechanisms. This study serves as a proof-of-concept that nano-enzyme mimics can be used to evaluate antioxidant capabilities and to screen enzyme inhibitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Self-citation
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Standardized assays for determining the catalytic activity and kinetics of peroxidase-like nanozymes
Jiang, B., Duan, D., Gao, L., Zhou, M., Fan, K., Tang, Y., Xi, J., Bi, Y., Tong, Z., Gao, G. F., et al. (2018) · Nature Protocols · doi:10.1038/s41596-018-0001-1 · Cited by 1,300
Recent Advances in Nanozyme Research
Wang, H., Wan, K., & Shi, X. (2019) · Advanced Materials · doi:10.1002/adma.201805368 · Cited by 974
A Review on Metal- and Metal Oxide-Based Nanozymes: Properties, Mechanisms, and Applications
Liu, Q., Zhang, A., Wang, R., Zhang, Q., & Cui, D. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00674-8 · Cited by 745
Metastable α-AgVO3 microrods as peroxidase mimetics for colorimetric determination of H2O2
Wang, Y., Zhang, D., & Wang, J. (2018) · Microchimica Acta · doi:10.1007/s00604-017-2562-z · Cited by 536
Metadata
- Authors
- Jia, H., Yang, D., Han, X., Cai, J., Liu, H., & He, W.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 8
- Issue
- 11
- Pages
- 5938-5945
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2285544726
- Cited by
- 213
- References
- 1
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peroxidase-like activity of the Co3O4nanoparticles used for biodetection and evaluation of antioxidant behavior. https://app.cochat.ai/papers/10.1039/c6nr00860g
- The paper
- Jia, H., Yang, D., Han, X., Cai, J., Liu, H., & He, W. (2016). Peroxidase-like activity of the Co3O4nanoparticles used for biodetection and evaluation of antioxidant behavior. Nanoscale. https://doi.org/10.1039/c6nr00860g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.