The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Highly sensitive biosensors based on all-dielectric nanoresonators
Abstract
Biosensing based on nanophotonic structures has shown a great potential for cost-efficient, high-speed and compact personal medical diagnostics. While plasmonic nanosensors offer high sensitivity, their intrinsically restricted resonance quality factors and strong heating due to metal absorption impose severe limitations on real life applications. Here, we demonstrate an all-dielectric sensing platform based on silicon nanodisks with strong optically-induced magnetic resonances, which are able to detect a concentration of streptavidin of as low as 10−10 M (mol L−1) or 5 ng mL−1, thus pushing the current detection limit by at least two orders of magnitudes. Our study suggests a new direction in biosensing based on bio-compatible, non-toxic, robust and low-loss dielectric nanoresonators with potential applications in medicine, including disease diagnosis and drug detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
High‐Efficiency Dielectric Huygens’ Surfaces
Decker, M., Staude, I., Falkner, M., Dominguez, J., Neshev, D. N., Brener, I., Pertsch, T., & Kivshar, Y. S. (2015) · Advanced Optical Materials · doi:10.1002/adom.201400584 · Cited by 1,334
Self-citationNon-plasmonic nanoantennas for surface enhanced spectroscopies with ultra-low heat conversion
Caldarola, M., Albella, P., Cortés, E., Rahmani, M., Roschuk, T., Grinblat, G., Oulton, R. F., Bragas, A. V., & Maier, S. A. (2015) · Nature Communications · doi:10.1038/ncomms8915 · Cited by 520
Cited by
Ultrasensitive hyperspectral imaging and biodetection enabled by dielectric metasurfaces
Yesilkoy, F., Arvelo, E. R., Jahani, Y., Liu, M., Tittl, A., Cevher, V., Kivshar, Y., & Altug, H. (2019) · Nature Photonics · doi:10.1038/s41566-019-0394-6 · Cited by 1,015
Self-citationAdvances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Dielectric Metasurfaces Enabling Advanced Optical Biosensors
Tseng, M. L., Jahani, Y., Leitis, A., & Altug, H. (2021) · ACS Photonics · doi:10.1021/acsphotonics.0c01030 · Cited by 330
Jahani, Y., Arvelo, E. R., Yesilkoy, F., Koshelev, K., Cianciaruso, C., De Palma, M., Kivshar, Y., & Altug, H. (2021) · Nature Communications · doi:10.1038/s41467-021-23257-y · Cited by 304
Self-citationVaskin, A., Kolkowski, R., Koenderink, A. F., & Staude, I. (2019) · Nanophotonics · doi:10.1515/nanoph-2019-0110 · Cited by 276
Self-citationRefractive index sensor based on all-dielectric gradient metasurface
Rodionov, S. A., Remnev, M. A., & Klimov, V. V. (2019) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2019.100263 · Cited by 258
All-Dielectric Surface-Enhanced Infrared Absorption-Based Gas Sensor Using Guided Resonance
Chang, Y., Hasan, D., Dong, B., Wei, J., Ma, Y., Zhou, G., Ang, K. W., & Lee, C. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b16623 · Cited by 115
Metadata
- Authors
- Bontempi, N., Chong, K. E., Orton, H. W., Staude, I., Choi, D.-Y., Alessandri, I., Kivshar, Y. S., & Neshev, D. N.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 9
- Issue
- 15
- Pages
- 4972-4980
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2600861782
- Cited by
- 165
- References
- 3
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.