The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly transparent AgNW/PDMS stretchable electrodes for elastomeric electrochromic devices
Abstract
Stretchable conductors based on silver nanowires (AgNWs) and polydimethylsiloxane (PDMS) have been studied extensively for many years. However, it is still difficult to achieve high transparency with low resistance due to the low attractive force between AgNWs and PDMS. In this paper, we report an effective method to transfer AgNWs into PDMS by using substrates which have a hydrophobic surface, and successfully prepared stretchable AgNW/PDMS electrodes having high transparency and low sheet resistance at the same time. The obtained electrodes can be stretched, twisted, and folded without significant loss of conductivity. Furthermore, a novel elastomeric HV electrochromic device (ECD) fabricated based on these stretchable AgNW/PDMS hybrid electrodes exhibited excellent electrochromic behavior in the full AgNW electrode system and could change color between colorless and blue even after 100 switching cycles. As most existing electrochromic devices are based on ITO and other rigid conductors, elastomeric conductors demonstrate advantages for next-generation electronics such as stretchable, wearable, and flexible optoelectronic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Emerging Electrochromic Materials and Devices for Future Displays
Gu, C., Jia, A.-B., Zhang, Y.-M., & Zhang, S. X.-A. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c01055 · Cited by 833
Viologen-based electrochromic materials and devices
Madasamy, K., Velayutham, D., Suryanarayanan, V., Kathiresan, M., & Ho, K.-C. (2019) · Journal of Materials Chemistry C · doi:10.1039/c9tc00416e · Cited by 490
All-Transparent Stretchable Electrochromic Supercapacitor Wearable Patch Device
Yun, T. G., Park, M., Kim, D.-H., Kim, D., Cheong, J. Y., Bae, J. G., Han, S. M., & Kim, I.-D. (2019) · ACS Nano · doi:10.1021/acsnano.8b08560 · Cited by 429
Highly Efficient and Reliable Transparent Electromagnetic Interference Shielding Film
Jia, L.-C., Yan, D.-X., Liu, X., Ma, R., Wu, H.-Y., & Li, Z.-M. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b00492 · Cited by 293
Metadata
- Authors
- Liu, H.-S., Pan, B.-C., & Liou, G.-S.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 9
- Issue
- 7
- Pages
- 2633-2639
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2578332810
- Cited by
- 172
- References
- 1
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly transparent AgNW/PDMS stretchable electrodes for elastomeric electrochromic devices. https://app.cochat.ai/papers/10.1039/c6nr09220a
- The paper
- Liu, H.-S., Pan, B.-C., & Liou, G.-S. (2017). Highly transparent AgNW/PDMS stretchable electrodes for elastomeric electrochromic devices. Nanoscale. https://doi.org/10.1039/c6nr09220a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.